OBID i-scan
®
System-Manual
ID ISC.MR/PR/PRH101
FEIG ELECTRONIC GmbH
Page 35 of 131
H60301-3e-ID-B.doc
D-START:
This parameter defines the first byte in the raw data (defined by DB-ADR and D-LGT), which
will be transferred in Scan-Mode. To transfer the whole data block D-START must be set to 0.
Note:
The size of one data block depends on the type of Transponder.
The maximum number of the transferred data bytes depends on the reader type and configuration
settings and the used sign type.
hex-formatted
ASCII formatted
without serial
number
with serial
number
with 1 separation
character
without serial
number
with serial
number
with 1 separation
character
RS232/
485
128 signs
128 signs
128 signs
80 signs
72 signs
71 signs
USB
40 signs
40 special char.
32 signs
32 special char.
32 signs
32 special char.
80 signs
53 special char.
64 signs
43 special char.
63 signs
42 special char.
* Only characters from A to X and 0 to 9 are non special character.
Note:
If an USB-Reader is used in Scan mode and “ASCII formatted hex-data” is configured it will be
distinguish between letters, numbers and special character(symbols). The special characters
will be first changed into the Unicode than into the USB-Keycode. Therefore you can transfer