OBID i-scan
®
System-Manual
ID ISC.MR/PR/PRH101
FEIG ELECTRONIC GmbH
Page 62 of 131
H60301-3e-ID-B.doc
6.1.3. [0x22] Lock Multiple Blocks
This command locks one or more data blocks.
The supported ISO15693Host commands depend on the different ISO15693 Transponder types, they
are described in chapter
9.1. Supported ISO15693 Host commands for ISO15693 Transponders
.
REQUEST-DATA
4
5
(6...13)
6 / (14)
7 / (15)
0x22
MODE
UID
DB-ADR
DB-N
RESPONSE-DATA (STATUS = 0x03)
5
DB-ADR-E
RESPONSE-DATA (STATUS = 0x95)
5
6
ISO15693
ERROR
DB-ADR-E
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
ADR
ADR:
b000
non-addressed
b001
addressed
b010
selected
UID:
Read only serial number of the Transponder. The UID is required only in the addressed mode.
DB-ADR:
First block number to be locked. First block can be any value between 0 and 255.
DB-N:
Number of data blocks to be locked, starting at DB-ADR.
The maximum number of DB-N, depends on DB-Size and the interface transmit buffer size
TX-BUF. The maximum number of DB-N is:
(TX-BUF - 10 )/(DB-
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS = 0x95.
DB-ADR-E:
Block number where the error occurred.