OBID i-scan
®
Installation
ID ISC.MRU200
FEIG ELECTRONIC GmbH
Page 46 of 52
M70201-4de-ID-B.doc
E
N
G
L
I
S
H
5
Operating and Display Elements
5.1 LEDs
Table 5-1 shows the LED configuration.
Table 5-1: LED configuration
Abbreviation
Description
LED V1 (green)
"RUN-LED 1"
-
Indicates proper running of the internal Reader software
LED V2 (blue)
Diagnostic 1: RF communication / EEPROM status
-
Short flashing indicates errorless communication with a transponder
on the RF interface
-
Flashes alternately with V1 after a reset following a software update
-
Flashes alternately with V1 in case of a data error when reading the
parameters after a reset
LED V3 (yellow)
Diagnostic 2: Host communication
- Short flashing indicates sending of a protocol to the host
LED V4 (red)
Diagnostic 4: RF warning
-
Comes on when there is an error in the RF section of the Reader.
The error type can be read out via software over the RS232/RS485
interface
5.2 Reset Button
Pressing the button T1 resets the reader.