Identifikation System OBID
i-scan
Page 16 of 20
FEIG ELECTRONIC GmbH
E N G L I S H
4. Assembly and Wiring
The antenna is intended for indoor use, e.g. on a table or the top of wall. Keyholes are provided on
the back side of the antenna for mounting (Fig. 1).
Fig. 1: Hole spacing
All dimensions in mm.
Do not place the antenna directly on metal. A minimum separation of 2 cm must be
maintained. At separations less than 10 cm the read range will be significantly re-
duced.
337±1
(38,5)
90
13
0
237
±
1
10
4,
5
7
(53,
5)
(73,
5)
keyholes
rubber feet
260