MVK 01/06
All rights reserved by FEIN, in particular as these apply to trademarks.
FEIN retains all powers of disposition such as copying and right of transfer
.
FRT: EVO WSB and WSG - Variants
11/118
3.1.1. Minor functional test: WSB 8-115 + WSB 13-125
Without main power
•
Check assembled cable (290) and protective tubing (270) for signs of
damage
•
Can the lever (480) be adjusted and does it snap in smoothly?
•
Can clamping bolt (680) be tightened / loosened?
•
Is flange (670) free of damage?
•
Are the cooling and ventilation slots free of obstructions?
•
Is the fan wheel at the armature (750) free of damage?
With main power
•
Plug in mains plug
•
Start motor using switchpad (95) and lock it
•
The motor must not start while the lever (810) is open
•
Motor must brake when turned off using switchpad (95)