4.2.2. Speed control / removal
Tools:
•
Screw driver 2.5x75
•
Bolts M3x18
1.
Remove cable strands from strand guide of
speed controller (80).
2.
Insert two M3x18 bolts into the bore holes of the
field magnet unit (10). Lightly press the bolts
together (loosen lock) and remove speed
controller.
3.
Unlock ribbon cable plug from switching module
(60) and unplug it.
1.
2.
3.
4.
5.