15
en
Insulated gripping surfaces
Hold power tool by insulated gripping sur-
faces, because the belt may contact its own
cord.
Cutting a “live” wire may make exposed
metal parts of the power tool “live” and could
give the operator an electric shock.
Repair and customer service.
Before mounting or replacing application tools or accessories, pull the power
plug.
This preventive safety measure rules out the danger of injuries through
accidental starting of the power tool.
Service.
Have maintenance carried out
only through qualified person-
nel. Incorrectly mounted leads and compo-
nents can cause serious injuries.
Have the
required service carried out only through a
FEIN customer service agent.
Cleaning.
Prior to any cleaning or main-
tenance, disconnect the power
tool from the power supply in order to avoid
accidents.
When using in environments
with conductive dust in the air,
such as when working metals, this dust can
settle in the interior of the power tool. This
can impair the total insulation of the power
tool. Therefore, regularly blow out the interior
of the power tool from outside via the ventila-
tion openings with dry, oil-free compressed
air; always wear eye protection when doing
this. For additional protection, connect a
ground fault circuit interrupter (g.f.c.i.) on the
line side.
Do not attempt to clean
clogged or dirty ventilation
openings of the power tool with pointed
metal objects; use non-metal tools or objects
for this.
Do not use cleaning agents
and solvents that can cause
damage to plastic parts.
These include: Gaso-
line, carbon-tetrachloride, chloric solvents,
ammonia and domestic cleaning agents that
contain ammonia.
If the supply cable of this
power tool is damaged, it
must be replaced by a specially prepared cable
available through the FEIN customer service
center.
WARNING
WARNING
WARNING
WARNING
CAUTION
CAUTION
CAUTION
OBJ_BUCH-0000000020-001.book Page 15 Thursday, December 9, 2010 8:48 AM