background image

Edition 08/2018. All rights reserved. 

www.feinmetall.com

Introduction

Please read these operating instructions carefully before use. Even if you already have experience with FEINMETALL 

tools.

Available guiding sleeves (HZ) and thread inserts (BZ):

Combination: 

   Receptacles:

•  BZ-075-01-1 & HZ-075-01-1 

 

H121; H075; H175; H176; H310; H561; H701; H863

•  BZ-100-01-1 & HZ-100-01-1   

H722; H727; H732; H752; H756; H757; H772; H875; H878

•  BZ-100-02-1 &HZ-100-01-1 

 

H320; H610; H865

•  BZ-100-02-1 & HZ-100-02-1   

H100; H502; H708; H731; H751; H805

•  BZ-157-01-1 & HZ-157-01-1 

 

H762; H866; H867; H887 

•  BZ-157-01-1 & HZ-157-01-2 

 

H723; H733; H737; H760; H761; H773; H774; H880; H881; H884; H885

Further variants are updated on the homepage under 

PRODUCT FINDER/ACCESSORIES-CP/FZWZ

Below you will find step-by-step instructions for handling the tool. 

Operating Instruction  

RECEPTACLE REMOVAL TOOL (FZWZ) 

Important:

 

Always lock the tool 

before mounting!

Assembly

01 - Handle (GSFZWZ)

02 - Thread insert (BZ) 

03 - Guiding sleeve (HZ) 

04 - Screw-nut (SOFZWZ-001)

01

02

03

04

Basic Kit FZWZ-SET-001

Contents:

•  Handle with mounted  

screw nut  (SOFZWZ-001)

•  Box for single parts

•  pliers

•  One BZ-100-01-1 

and HZ-100-01-1 each

Reviews: