23
FS 700 K
Technical information
Data
Value Unit
Oscillating frequency 60 Hz
27 per min.
4.5
Storage conditions of the sanding belts
●
Temperature from 16 to 25 degrees celsius (60 to 80 degrees fahrenheit).
●
Relative humidity from 40 % to 60 %.
4.6
Dust extraction
Data
Value Unit
Extraction connection diameter
140 mm
Minimum negative pressure
1310 pa
Air speed
20 m/s
Minimum volume flow (at 20 m/s)
1110 m
3
/h
4.7
Dust emission
The working areas of this machine are considered dust-minimised according to
DGUV Information 209-044. The maximum concentration level of 2 mg/m³ of
inhalable dust in the air will not be exceeded.
This only applies if the conditions that are specified in the section "Extraction" are
adhered to.
4.8
Noise emission
Measurement in accordance with EN ISO 19085-1:2021 appendix E:
●
with ISO 11202 for the emission noise pressure with accuracy level 3
●
due to the background noise
If the stated noise emission values are to be checked, then the measurements must
be taken following the same procedure and in the same operating and installation
conditions as described.
WARNING: The noise emission values stated are only valid, when the same
operating- and installation conditions apply. Other operation and installation con-
ditions, e.g. a different work process, can lead to higher noise emission values
with the danger of underestimation.
WARNING: The noise emission values stated are not exposure level values.
Although there is a correlation between emission and exposure levels, the emis-
sion values can not be used to reliably determine whether increased safety meas-
ures are required. Factors that influence the actual degree of exposure are the
actual work process, the exposure time, the characteristics of the workplace and
other neighbouring noise sources in the workshop.