background image

4

5

Place the air purifier face up on a 

flat, stable work surface. Open the 

access panel by pressing in latches 

on each side of the unit (Fig 3). 

Make sure filters are in correct order 

-  pre-filter  /  carbon  filter  /  HEPA 

filter - and inserted into filter frame 

(Fig 16).

IMPORTANT: Make sure filter 

detection area aligns with window 

in filter frame (Fig 17).

Disconnect main housing assembly 

from rear housing assembly. 

Separate main housing from rear 

housing. Lift main housing assembly 

away from rear mounting housing 

(Fig 8).

Close front panel by pressing 

firmly until both sides latch closed 

(Fig 19).

Open access panel and remove 

filter assembly by pulling out on 

top of side edges of frame, then 

lifting.  NOTE:  remove  all  plastic 

wrap from filters (Fig 4).

The  power  connector  (B,  in  Fig 

12)  will  carry  power  from  the  rear 

housing to the main housing once 

the assemblies are fully seated. The 

main assembly will attach to the rear 

housing assembly by the four screws 

previously removed (Fig 5 & 6). Two 

snap hooks (A, in Fig 12) will hold the 

main and rear assemblies together 

until the screws can be installed.

Remove the six housing screws (Fig 5 & 6) and set aside for re-assembly.

Carefully align the main assembly 

with the rear housing assembly. 

Slowly press into place until snap is 

heard, and there is no gap between 

the  assemblies  (Fig  13).  The  unit 

should now support its own weight.

At the location of the two upper 

housing corner screws (Fig 5), insert 

a flat head screwdriver and gently 

twist to release tab as shown in Fig 

7. This will disconnect main housing 

assembly from the rear housing 

assembly.

Open front panel by pressing 

latches on both sides of unit. Allow 

door to open fully. Insert filters 

–  IMPORTANT: make sure filter 

detection window is aligned in 

upper right corner (Fig 18).

To restrict access to the control panel 

and filters the unit can be locked. To 

lock, insert the key provided and 

rotate clockwise ¼ turn (Fig 21). 

Once  the  unit  is  closed  re-establish 

power. Lights on the control panel will 

be visible through the lens, indicating 

the unit is operational (Fig 20). The 

power light indicator will flash once 

a second.

Install  six  screws  (previously  removed)  to  secure  main  assembly  to  rear 

housing assembly (Fig 14 & 15).

MOUNTING REAR HOUSING AND MAIN ASSEMBLY

RE-INSTALLING FILTERS

LOCKING ACCESS PANEL

MAIN ASSEMBLY INSTALLATION

REAR HOUSING INSTALLATION & WIRING

Test the electrical outlet box first to ensure rated power requirements are met before beginning installation. 
Remove air purifier from its shipping carton and remove all packing material. 

Reference rear housing and locate desired mounting location. Again, it is strongly recommended at least 2 mounting anchors for the air purifier be mounted to 

an existing stud. 

WARNING:

 

To avoid the risk of electrocution confirm the electrical supply has been disconnected or switched off before continuing any installation work.

IMPORTANT:

 

Make sure all plastic wrap is removed from filters.

Fig 3

Fig 7

Fig 16

Fig 17

Fig 18

Fig 19

Fig 20

Fig 21

Fig 4

Fig 8

Fig 5

Fig 14

Fig 12

Fig 13

Fig 6

Fig 15

Fig 10

Fig 11

1

2

3

4

5

6

1

2

3

4

5

6

Using provided template ensure electrical 

outlet box is located behind cable hole (A) 

in  Rear  Housing  assembly  (Fig  9).  Drill 

holes and place anchors in wall.
If mounting on concrete, cinder block or 

brick type walls route the wires through 

the “punch-out” hole marked (B) in Fig 9.

Check for washers at all mounting 

screw  locations  (Fig  10).  Pull  wires 

from electrical outlet box through 

hole in rear housing. Align housing 

over anchors and securely install all 

mounting screws.

Attach wires from electrical outlet box to wires located inside rear housing using wire nuts.  Match up line (black) and neutral (white) wires (Fig 11).  Make sure 

all connections are made in accordance with federal, state and local codes and regulations. 

A

B

A

B

A

A

B

Fig 9

AeraMaxPRO_AMIV_InstallGuide_408531_RevB_111314.indd   4-5

11/13/14   11:02 AM

Reviews: