background image

Page 7

Step #10: make cable and cord connections

•  Connect the cable from the digital keypad to the control unit.

•  Connect the motor cables to the control unit and to the short cable from each table leg.

•  Connect the power cord to the control unit.

•  Plug the power cord into an AC outlet. Be sure the cord can reach the outlet when  

the table is raised to its highest position.

CAUTION:

 Do not operate the table until after initializing the system. See the  

following step.

 

VictoryLX 3-leg 

Assembly

Step #8: attach digital keypad 

•  Attach the digital keypad using the three M3x20 #1 Phillips round head screws.

•  Install the keypad in the “expanded” position. Pull the keypad away from the 

mounting bracket to expand it.

•  Position the digital keypad on the left or right side of the table, according to user 

preference.

•  Align the top of the keypad with the edge of the table so that the controls will be 

easily accessible in the expanded position.

 

— To prevent accidental damage when not in use, the keypad may be pushed in, 

under the table.

Step #9: attach control unit

•  Position the control unit near the back of the table or between the  

cross channels.

•  Be sure that the cable from the keypad can reach the control unit and the  

motor cables can extend from the control unit to all three leg motors.

•  Attach the control unit using the two M5x25 #2 Phillips round head screws.

 

— Tighten the screws securely.

NOTICE:

 The table may not operate properly if the control unit is not 

securely attached to the worksurface.

M5x25 #2 Phillips

round head

control unit

M3x20 #1 Phillips

round head

digital

keypad

align with

edge of table

when expanded

motor

cables

power

cord

keypad

cable

Summary of Contents for ESI Victory 3V-LX-C4848-24 Series

Page 1: ...ictory LX 3 Leg Model 3V LX C4848 24 ___ Model 3V LX C4848 30 ___ Model 3V LX C4836 24 ___ Model 3V LX C4836 30 ___ Model 3V LX C3636 24 ___ Model 3V LX C3636 30 ___ ___ SLV BLK or WHT Electric height...

Page 2: ...Use power drill on self tapping screws only Always check that screws used to attach components to the worksurface are not too long for the thickness of the table table thickness top supports 2 motor c...

Page 3: ...screws on each of the frame segments Attach the center leg bracket to the left frame segment The longer section of the cross channel at the open end should be at the top toward the rear of the table...

Page 4: ...cross channels see below Position the rear cross channels 6 5 or 9 5 from the rear edge of the table depending on table depth 6 5 for tables 24 deep and 9 5 for tables 30 deep The center leg bracket s...

Page 5: ...e cam lock is installed rotate its lever arm toward the leg until the lever is horizontal This locks the leg in place Install the cotter pin to secure the cam lock Check to be sure each leg is securel...

Page 6: ...ing into the notches Then push the protrusions back into the narrower part of the notches Install the remaining cam lock With the lever arm upward insert the long end of the cam lock first as shown Af...

Page 7: ...keypad on the left or right side of the table according to user preference Align the top of the keypad with the edge of the table so that the controls will be easily accessible in the expanded positi...

Page 8: ...ecure and check that the control unit is securely attached to the worksurface If problems continue call ESI Customer Service 800 833 3746 NOTICE The table must be re initialized when power is restored...

Page 9: ...e feet and center leg to level the worksurface Plug the power cord into an AC outlet Re initialize the system See Step 11 on page 8 IMPORTANT Be sure there are no obstacles under the table that would...

Page 10: ...ating the lower stop position has been erased Release both buttons VictoryLX 3 leg Operation UP button memory buttons digital display DOWN button SET button Upper stop position To set the upper stop p...

Page 11: ...ON to normalize communication 2 Table is tilted straighten table or wait one minute before operating table IMPORTANT The table should be re initialized after every 1 000 cycles every six months or if...

Page 12: ...MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL RETAIL PURCHASE ESI s sole obligation under this warranty or any implied warranty and...