12
V . S P E C I F I C A T I O N S
DC Power Pack:
• Rechargeable NiCd cells
• 14.4 VDC nominal voltage
• 2.4 Amp hour
• DC Power Pack Run Time-See pg.20
Triggering
Internal
•30 Flashes / Min (F/M) to 18000 F/M
• Automatically limits to max rate of selected intensity
level (6000 F/M, 12000 F/M, 18000 F/M)
• 1 F/M resolution
• 100 ppm/°C accuracy
External
• Video 1vp-p unterminated, triggers from 50Hz-60Hz
vertical sync
• Pulse Source: > +2.5v pk, 100µsec min pulse width
Input impedance 10kž
• Contact Closure: > 8 VDC @ 10mA rating
• 0-360 Degree phase delay adjustment available when
using external triggering.
• Phase delay accuracy ± 1 degree
Trigger Sensor Supply:
+14.4 VDC nominal, internally connected to a
DC Power pack
Trigger to Flash Delay: 5µsec
Time Base Accuracy: .01%
Temperature Stability: ±.01% per °C
Update Time: 100msec