background image

INSTALLATION GUIDE

AXISS FUSION PLUS® SHOWER MIXER BLACK 

AXFSPCSMB

SYSTEM REQUIREMENTS

Operating Pressures - refer to the Venturi Selection Table on page 2

Unequal Pressure - Venturi jet installed

Operating Pressures

Equal High (Mains) & Equal Low Pressures - Venturi jet removed

Operating Hot Water Temperatures

Operating Cold Water Temperatures

Do not plug outlet when testing.

This shower mixer can be line tested up 1500kPa (217.6psi)

MINIMUM

MAXIMUM

36kPa (5.1psi)

36kPa (5.1psi)

200kPa (29.0psi)

1500kPa (217.6psi)

1500kPa (217.6psi)

55° C

60° C

5° C

N/A

Hot

Cold

AS/NZS 3500.1 states that pressures above 500kPa can cause damage from water hammer, reduce the life of 
appliances, taps & fittings, cause excessive noise in the system and recommend that a pressure limiting valve (PLV) be fitted.

WHAT IS IN THE PACK

Mixer Assembly

2.5mm Allen Key

8g x 32 Dome Head
Square Drive
Stainless Steel Screws

Grub Screw

Handle Cap

2x Venturi Jets for Unequal Pressures

Round Top

Hex Top

Red

O-ring

Black

O-ring

TOP VIEW

TOP VIEW

Handle

Fac O-Ring

BEFORE INSTALLATION

MIXER ORIENTATION

Pipework MUST be purged before connecting to the mixer

This mixer is designed to be connected with the hot water 
supply on the left only and the cold water supply on the 
right only.
If at any point the nut is removed, please ensure that both 
black lines marked on the cartridge and cartridge nut are 
aligned when the mixer is in full cold position as shown in 
figure 1.

HOT

INLET

ONLY

COLD

INLET

ONLY

( FULL COLD POSITION )

Figure 1.

OUTLET

Page 1

Patented New Zealand No. 605175 

IMPORTANT:

Factory fitted 

WITHOUT

Venturi Jet

Reviews: