background image

Page 5

UPGRADING FROM UNEQUAL TO MAINS PRESSURE

MAINTENANCE - CLEANING THE FILTER

Remove the insert disc using long nosed pliers by carefully 
inserting the nose of the pliers into the indicated areas A & B.

2.

AREA A

AREA B

Remove the handle and disassemble the mixer:

1.

Unscrew the Venturi Jet using a 2.5mm Allen Key

3.

4.

REVERSE VIEW OF DISC

Locating pin socket

FRONT VIEW OF DISC

Locating pin

Reassemble mixer. Ensure that both black lines marked on the 
cartridge and cartridge nut are aligned when the mixer is in full 
cold position as shown in figure 1 (Page 1).

5.

Locating pin

Refit the seal and then insert disc using the long nose pliers, 
ensuring that the locating pins go into the corresponding sockets.

1. Follow steps 1-2 above.
2. Flush out the disc in cold water.
3. Follow steps 4-5 above.

FILTER

REVERSE VIEW OF DISC

Patented New Zealand No. 605175 

Reviews: