Page 5
UPGRADING FROM UNEQUAL TO MAINS PRESSURE
MAINTENANCE - CLEANING THE FILTER
Remove the insert disc using long nosed pliers by carefully
inserting the nose of the pliers into the indicated areas A & B.
2.
AREA A
AREA B
Remove the handle and disassemble the mixer:
1.
Unscrew the Venturi Jet using a 2.5mm Allen Key
3.
4.
REVERSE VIEW OF DISC
Locating pin socket
FRONT VIEW OF DISC
Locating pin
Reassemble mixer. Ensure that both black lines marked on the
cartridge and cartridge nut are aligned when the mixer is in full
cold position as shown in figure 1 (Page 1).
5.
Locating pin
Refit the seal and then insert disc using the long nose pliers,
ensuring that the locating pins go into the corresponding sockets.
1. Follow steps 1-2 above.
2. Flush out the disc in cold water.
3. Follow steps 4-5 above.
FILTER
REVERSE VIEW OF DISC
Patented New Zealand No. 605175