background image

Body

Rose

Assembly

pips

45 mm

from back

of mixer

to front of

shower

wall Lining.

64 mm

Height

of

recess.

Installation Instructions

FELTONMIX

®

 Shower Valves

Types U, E and H

1.  Provide  a  stud  or  other  suitable  fi xing  in  the 

shower wall on which to mount the shower valve 

Shower head at about eye level (between 1.5 and 

1.8 metres) is a good guide. Ensure distance from 

mounting face to front of wall lining is 

45mm.

2. 

Flush  out  pipework

.  Mount  shower  valve 

assembly  and  secure  with  two  wood  screws 

provided. 

It is important 

that the pipes which are 

now connected directly to the isolator valves on 

each side of the shower valve assembly line up 

correctly with the isolators and do not place any 

unnecessary strain on the valve assembly. Ensure 

isolators are open, (turn anticlockwise).

Do not apply heat to pipes connected to the mixer 

as internal damage may occur.

Note:

 When tightening crox nuts it is important to 

hold the hexagon face to prevent any strain on the 

isolator. 

Do not attempt to tighten or remove 

the  brass  nipple  from  the  isolator. This  has 

been installed with correct pre-loading at the 

factory and any alteration may cause damage 
to the isolator.

3. Cut an access hole in the wallboard to suit the 

shape of the wallplate using the template provided.
4. Position the wallplate over the valve outlet and 

fi t the two 1

1

/

8

 x 7 screws provided through each 

wallplate slot and into the valve body lugs. Tighten 

screws alternately until wallplate is fi rmly clamped 

to the wall.

Warning:

Do not overtighten. Light pressure is suffi cient 

to clamp the wallplate fi rmly.
5.  Rotate  slotted  sleeve  on  valve  body 

(projecting  from  central  hole  of  wallplate 

anticlockwise  and  fi t  handle  to  sleeve, 

locating  at  the  4  o’clock  position.  Handle 

should recess into the wallplate and match 

its contours.  Ensure that handle has about 

10 mm of engagement.

6.  Screw  showerhead  into  valve  assembly 

until  full  home.  If  necessary  unscrew  the 

showerhead part of a turn to bring it to the 

correct position. The O-ring seal fi tted to the 

showerhead  stem  will  ensure  a  watertight 

seal.  Tape  or  hemp  on  the  thread  is  not 

necessary or desirable.

7. CHECK OPERATION. When installed check 

that the handle swins from right to left from 

OFF to HOT. Total movement is about 130°.

SHOWER HEAD

Insuffi cient Water Flow:

Check that the correct model (Type U, 

Type E or Type H) has been installed for 

the supply conditions. Check fi lters for 
foreign

 matter.

Insuffi cient Hot Water:

Check that isolators are fully open 

(unscrewed anticlockwise) Check that 

suffi cient water pressure is reaching the 

valve. A minimum of 20 kPa (3 p.s.i.) fl ow 

pressure is recommended.

Inadequate hot water temperature and/or 

fl ow may also be experienced if a

tempering valve is fi tted and is not 

installed strictly in accordance with the
manufacturer’s instructions.

Valve does not shut off properly:

Check seals.

Water leaks from behind handle:

If water is leaking from under slotted 

sleeve when shower is on it will be 

necessary to replace O-ring seals on rotor.

(see a/so Service Notes)

To protect your investment, use only Genuine Feltonmix Spare Parts. Substitutes 
may damage the Feltonmix product. Authorised parts carry the description

GENUINE SPARE PARTS MANUFACTURED BY FELTONMIX LTD, AUCKLAND, N.Z.

TROUBLE SHOOTING

Your Feltonmix shower head is manufactured 
from self-cleaning plastic materials and cleaning 
with a soft nylon brush and bathroom cleaners is 
usually suffi cient.
If dismantling is required, insert the two leg’s 
of the Feltonmix spanner into the face 
of the rose. Turn the rose approximately 
thirty degrees and withdraw it from the 
shower head body.
When assembling ensure that the sharp 
outer edge of the soft spray ring is 
located at the front edge of its support 
ring. Align the assembly pips on the front face 
of the rose and lip of the body. Push them together 
until they click twice.

Manufactured by

 

FELTON INDUSTRIES  LTD

Freephone 0800 PH FELTON (0800 743 358)

Free Fax 0800 FAX FELTON (0800 329 335)

www.felton.co.nz