12. TROUBLESHOOTING
In case that electric fence system does not work properly, so there are some tips for troubleshooting.
Cause
Fault removal
Energizer does not work?
Disconnect the device from the fence system and switch
it on again! If blue or violet LED is burning and yellow
or green LED is flashing on BARGRAPH indicator, then
the device works properly. Otherwise, the device is
damaged (contact your salesman). When using battery
and accumulator devices, observe correct wiring of poles.
Red LED light is blinking
Battery voltage decreased below 12 V - replace the battery
with a sufficiently charged one or connect adapter.
Red LED light is blinking and warning siren
sounds (beeping)
Battery voltage decreased below 11,6 V - replace the
battery with a sufficiently charged one or connect adapter.
No LED signal is burning
Energizer is switched off manually or battery voltage
decreased below 11,4 V and energizer was switched off
automatically. Reason is protection of battery from its
deep discharge (and battery destruction). Replace the
battery with a sufficiently charged one or connect adapter
– until battery voltage reaches at least 12 V, red LED will
be burning.
Lead-in or short circuit of supply lines of the fence
system
Do not use conventional cables for supply lines. High-
voltage cable is recommended.
Conductor has adverse properties (thin diameter,
high resistance)
Use high-quality conductor with low resistance and
larger diameter. Ensure high-quality correct connection
of conductors.
Low-quality earthing, too short earth rod,
corrosion, dry soil
Add next rod, moisten.
Lead-in via growth near fence system
Remove the growth (mow it).
Conductor on ground (for example break,
insufficient mechanical tension)
Repair fencing, use special connectors, stretch
conductor.
Too long fence system. Was correct accessories
used for given purpose?
Use accessories suitable for given length of fence system
and for animals – in case of need, consult specialized
salesman.
Insulator pierces, losses occur
Replace defective and weather-worn insulators.
Conductor is connected via knot, insufficient
connection
Use relevant special connectors for the conductor.
Displayed error message E1
Error in evaluation of output voltage. This condition
indicates that the fence system is not working properly.
Energizer´s power is limited to 5 J and the earthing
measuring does not work. It is necessary to send the
energizer to our Service Department for a specialist
inspection and repair.