background image

Feniex Industries, Inc.
1.800.615.8350
 /

 

feniex.com

5

LOCKING AND UNLOCKING PATTERN

SELECT AND COLORS

Once both pattern and color is set to the desired settings for all 
3 modes you can lock and unlock the color and pattern with the 
below instructions. This locking will disable the blue wire for color 
change and the green wire for pattern change. The blue wire can 
still be used to sync the modules once the locking is enabled.

■ 

Enabling Locking Features:

1. Attach ground to the black wire.
2. Twist Mode 1(Red wire), Mode 2(Yellow Wire), Mode 3 (White 
Wire), and Color Change(Green wire) together. Then apply 12V+ to 
them for 10 seconds.
3. After 10 seconds you should see the module light up Amber. 
After the Amber light turns off the module is locked and the user 
cannot change pattern or color on all modes.
4. Remove 12V+ from the wires listed in Step 2 and untwist all of 
them.
5. The locked unit is now ready to use.

■ 

Disabling Locking Features:

1. Attach ground to the black wire.
2. Twist Mode 1(Red wire), Mode 2 (Yellow Wire), Mode 3 (White 
Wire), and Color Change(Green wire) together. Then apply 12V+ to 
them for 10 seconds.
3. After 10 seconds you should see the module light up White. 
After the White light turns off the module is unlocked and the user 
can now change pattern or color on all modes again.
4. Remove 12V+ from the wires listed in Step 2 and untwist all of 
them.
5. The unlocked unit is now ready to use.