1. Place the lifting tower over a firm and flat 

surface on its working place.
2. Remove the outriggers (H) from their 

transport supports (C) by releasing the plas-

tic knob (V) and pull the outrigger (H) up. 

Insert them into their working position (G) 

checking that they are fixed by the safety pins 

(K). The longest outriggers must be placed at 

the front, under the load.
3. Remove the pin (L) from the transport 

plate (F) and remove the forklift (E). Turn 

the winch handle (B) until the carriage (X) 

has raised enough that it does not touch the 

transport plate (F). Put the forklifts (E) in 

horizontal position and secure them with the 

pin (L).
4. Insert the outriggers (H) into their wor-

king position (G) checking that they are fixed 

by the safety pins (K). The longest outriggers 

must be placed at the front, under the load.
5. Adjust the lifting tower using the support 

plates (J) by turning the crank (I) of the re-

gulating rod until it is level, checking the sta-

bilizing bubble level (Y) located at the base.
6. Put the load as close to the lifting tower as 

possible. Do not unnecessarily separate the 

sound system from the lifting tower body to 

avoid overloading. See fig. 2 (page 17). Fo-

llow loading instructions. See fig. 3 (page 17).

7. Elevation: To lift the profiles, a specific or-

der must be followed. The first profile to be 

raised will always be the one located furthest 

from the winch. Release the safety pin (A) in 

open position (T) and turn the winch handle 

(B) clockwise, lifting the load until the desi-

red height. Immediately afterwards, close the 

safety pin (A) in position (S), until the end of 

the section has been reached. Go on succes-

sively to the different positions of each of the 

profiles, until the desired height is reached. In 

case the pin is hard to pull out, a small num-

ber of movements should be made with the 

winch until founding the right position whe-

re the pin is released and can be pulled out 

comfortably. Under no circumstances any of 

the pins should be pulled with force. In case 

of the lifting tower does not need to be raised 

to its maximum height, it is recommended to 

raise all the profiles proportionally according 

to the height, and not only one of them.
8. When using the lifting tower outdoors, the 

risk of wind is prevalent, for which there are 

two fixing side rings (M) in the upper part 

of the second profile, where safety cables 

must be attached and fixed on a secure and 

firm surface (never on a vehicle or anything 

that can move). When wind speed exceeds 

30km/h, it is mandatory to bring down the 

lifting tower.

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

A

C

J

G

M

B

X

I

H

V

K

F

Y

E

L

U

T

Summary of Contents for AT-04B

Page 1: ...erie Serial No Instrucciones Instructions Fabricante Manufacturer FENIX Stage S L U FENIX Stage S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain Tel 34 96 125 08 55 export fenixs...

Page 2: ...2 2 FENIX STAGE S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain...

Page 3: ...liability the conformity of the product Name Model Description to which this declaration refers as per the following regulations CE 2006 42 EG Person empowered to compile the technical file and autho...

Page 4: ...sions Fecha Date Verificador Verifier Firma Signature Partes comprobadas Tested parts Conclusiones Conclusions Fecha Date Verificador Verifier Firma Signature Partes comprobadas Tested parts Conclusio...

Page 5: ...p g 8 seguir las instrucciones de uso ver punto 4 p g 9 un manteniminto peri dico ver punto 5 p g 10 conocer los sistemas de prevenci n ver punto 7 p g 11 BGV C1 is a regulation for staging and pro d...

Page 6: ...E SEGURIDAD 8 4 INSTRUCCIONES DE USO 9 5 MANTENIMIENTO 10 6 RIESGOS ESPEC FICOS 10 7 SISTEMAS DE PREVENCI N 11 INDEX 1 INTRODUCTION 12 2 GENERAL DATA 12 2 1 Technical data 12 2 2 Applicable regulation...

Page 7: ...naci n TORRE ELEVADORA Modelo AT 04B Caracter sticas t cnicas Altura m xima 5 00m Altura m nima 1 59m Carga m xima 200kg Carga m nima 25kg Material Aluminio seg n AL Si 6082 T6 rea de la base abierta...

Page 8: ...elevadora ni apoyarlas en l para realizar ning n tipo de trabajo Tenga cuidado con todo tipo de salientes por encima de la torre elevadora como cornisas balcones letreros luminosos etc Es muy importa...

Page 9: ...ga Ver fig 3 p g 17 7 Elevaci n Para elevar los perfiles hay que seguir un orden concreto El primer perfil que hay que subir siempre ser el m s aleja do del cabestrante Liberar el gatillo de segu rida...

Page 10: ...os de carga E en posici n vertical y bajar el ca rro X girando la manivela del cabestrante B ejerciendo un poco de presi n sobre el carro X Meter las patas H en su sopor te para transporte C ajustando...

Page 11: ...N Sobre fallo del sistema de freno Disponer de cabestrante conforme a las nor mas mencionadas en la directiva de seguri dad BGV C1 especialmente DIN EN ISO 12100 2011 03 y DIN EN ISO 12100 1 2004 04 S...

Page 12: ...AT 04B Technical characteristics Maximum height 5 00m Minimum height 1 59m Maximum load 200kg Minimum load 25kg Material Aluminium AL Si 6082 T6 Workspace 1 45 x 1 49m Closed base area 0 38 x 0 48m W...

Page 13: ...lifting tower or lean against it for any kind of work Beware of any kind of projection above the lifting tower like cornices balconies luminous signs etc It is very important to avoid the presence of...

Page 14: ...loading instructions See fig 3 page 17 7 Elevation To lift the profiles a specific or der must be followed The first profile to be raised will always be the one located furthest from the winch Release...

Page 15: ...he safety pins A in closed position S Move the forklifts E in vertical position and lower the carriage X by turning the winch handle B and pressing down a little on the carriage X Place the outriggers...

Page 16: ...tions metioned in the BGV C1 directive spe cially DIN EN ISO 12100 2011 03 and DIN EN ISO 12100 1 2004 04 About loss of stability Maintenance of lifting tower stability must basically be as per the f...

Page 17: ...17 Distancia Distance Carga m xima Maximum load 20cm 200kg 45cm 160kg Distancia del centro de la carga a la torre Distance from the center of the load to the tower Figura 2 Figura 3 20cm 45cm...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20...

Page 21: ...21...

Page 22: ......

Page 23: ...23 NOTAS NOTES LIFTING TOWERS...

Page 24: ...FENIX Stage S L U FENIX Stage S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain Tel 34 96 125 08 55 export fenixstage com www fenixstage com www fenixstage com...

Reviews: