background image

95%, four constant-on: charging complete. 
4.

 

Replace the anti-dust cap to ensure waterproof and dustproof ability. 

 

Battery Level Indication 

 

With the lamp switched off, single click either switch to check the battery status, single click once 
again the lamp will go out immediately, or without any operation the status will last for 3 seconds. 
There will be no response with the lamp locked. 
Four lights on: 100% - 81% 
Three lights on: 80% - 61% 
Two lights on: 60% - 41% 
One light on: 40% - 21% 
One light flashes: 20% - 0% 
 

Battery Specifications   

Type 

Dimensions 

Nominal voltage 

Usability 

 

Fenix ARB-L18 Series 

18650 

3.6 V /3.7V 

Recommended 

√√ 

Non-rechargeable Battery 

(Li-ion) 

CR123A 

3V 

Usable 

√ 

Rechargeable Battery (Li-ion) 

16340 

3.6 V /3.7V 

Banned 

× 

Rechargeable Battery (Li-ion) 

18650 

3.6 V /3.7V 

Caution* 

 

Rechargeable Battery 

(LiFePO4) 

16340 

3.2V 

Banned 

× 

Rechargeable Battery 

(LiFePO4) 

18650 

3.2V 

Banned 

× 

*18650  Li-ion  batteries  are  powerful  cells  designed  for  commercial  applications  and  must  be 
treated with caution and handled with care. Only use quality batteries with circuit protection to 
reduce  the  potential  for  combustion  or  explosion;  but  cell  damage  or  short  circuiting  are 
potential risks the user assumes. 
Quality  Li-ion  battery  with  protective  circuit  will  reduce  risks.  Fenix  ARB-L18  Series  battery  is 
recommended.

 

 

Battery Replacement

 ④

 

Unscrew the battery cover anticlockwise to insert the battery with the anode side (+) towards 
the , then screw the battery cover back on. 
 

Low Voltage Warning   

When  the  battery  level  is  detected  critical  for  currently  used  output,  one  of  the  indicator  will 
flash to remind. Replace the battery or recharge the lamp as soon as possible. 
 

Headband Assembly 

 