1. Place the lifting tower over a firm and flat 

surface on its working place.
2. Remove the outriggers (H) from their 

transport supports (C) by pressing the safety 

pins (K) and insert them into their working 

position (G) checking that they are fixed by 

the safety pins (K). 
3. Adjust the lifting tower vertically using the 

support plates (J) by turning the cranks (I) of 

the regulating rod until it is leveled, checking 

the stabilizing bubble level (Y) located at the 

base.
4. Put the load on the top of the lifting tower 

using the suitable support, in order to make 

the load work only vertically. The minimum 

load must be 25kg.
5. Elevation: To lift the bars, follow a descen-

ding order, that is to say, the first bar to be lif-

ted will be always the highest one. Release the 

safety pin (A) in open position (T) and turn 

the winch handle (B) clockwise, lifting the 

load until the desired height. Immediately 

afterwards, move the safety pin (A) to clo-

sed position (S), until the end of the section 

has been reached. Go on successively to the 

different positions of each of the bars, until 

the desired height is reached. In case the pin 

is hard to pull out, a small number of move-

ments should be made with the winch until 

founding the right position where the pin 

is released and can be pulled out comforta-

bly. Under no circumstances any of the pins 

should be pulled with force. In case of the lif-

ting tower does not need to be raised to its 

maximum height, it is recommended to raise 

all the bars proportionally according to the 

height, and not only one of them.

6. Lowering: Follow an ascending order to 

lower the bars, that is to say, the first bar to 

be lowered will be the lowest one. To relea-

se the safety pins (A), the load must be lifted 

slightly with the winch. In the normal wor-

king position, the weight of the load prevents 

the safety pins (A) from being released. Once 

the safety pin (A) is released, move it to the 

open position (T), by doing (U) step. Then 

turn the winch handle (B) slightly counter-

clockwise. Immediately afterwards, move 

again the safety pin (A) to closed position 

(S), until the end of the section. Repeat the 

same steps successively until it is completely 

folded to its minimum height.
7. For the lifting tower transport, it is neces-

sary to bring down all bars and place the sa-

fety pins (A) in closed position (S). Place the 

outriggers (H) in their transport support (C) 

checking that the safety pins (K) are fixed in 

its correct position.

 

 

 

 

 

 

 

 

 

 

Summary of Contents for MEGARA 230

Page 1: ...No Instrucciones Instructions LIFTING TOWERS Fabricante Manufacturer FENIX Stage S L U FENIX Stage S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain Tel 34 96 125 08 55 export fe...

Page 2: ...FENIX STAGE S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain...

Page 3: ...bility the conformity of the product Name Model Description to which this declaration refers as per the following regulations CE 2006 42 EG Person empowered to compile the technical file and authorise...

Page 4: ...sions Fecha Date Verificador Verifier Firma Signature Partes comprobadas Tested parts Conclusiones Conclusions Fecha Date Verificador Verifier Firma Signature Partes comprobadas Tested parts Conclusio...

Page 5: ...unto 3 p g 8 seguir las instrucciones de uso ver punto 4 p g 9 un manteniminto peri dico ver punto 5 p g 10 conocer los sistemas de prevenci n ver punto 7 p g 11 BGV C1 is a regulation for staging and...

Page 6: ...E SEGURIDAD 8 4 INSTRUCCIONES DE USO 9 5 MANTENIMIENTO 10 6 RIESGOS ESPEC FICOS 10 7 SISTEMAS DE PREVENCI N 11 INDEX 1 INTRODUCTION 12 2 GENERAL DATA 12 2 1 Technical data 12 2 2 Applicable regulation...

Page 7: ...nicos Denominaci n TORRE ELEVADORA Modelo MEGARA 230 Caracter sticas t cnicas Altura m xima 5 30m Altura m nima 1 82m Carga m xima 230kg Carga m nima 25kg Material Acero seg n EN 10305 5 rea de la bas...

Page 8: ...po de trabajo Tenga cuidado con todo tipo de salientes por encima de la torre elevadora como cornisas balcones letreros luminosos etc Es muy importante evitar la presencia de cables por debajo de la a...

Page 9: ...gar a la altura deseada En el caso de que el gatillo est duro y sea dif cil de sacar hay que realizar un peque o juego con el cabestrante hasta encontrar la posici n exacta donde se libere el gatillo...

Page 10: ...e su territorio 6 RIESGOS ESPEC FICOS Fallo del sistema de freno Puede producirse por deficiencias en el siste ma de frenado o por una mala instalaci n Si deja de funcionar puede provocar un riesgo im...

Page 11: ...las torres de forma segura Sobre ca da de objetos a distinto nivel golpes y o contusiones con objetos El riesgo de ca da de objetos a distinto nivel puede prevenirse con la utilizaci n de elementos d...

Page 12: ...MEGARA 230 Technical characteristics Maximum height 5 30m Minimum height 1 82m Maximum load 230kg Minimum load 25kg Material Steel EN 10305 5 Open base area 2 x 2m Closed base area 0 47 x 0 47m Weight...

Page 13: ...r element which might move Never use a ladder over the lifting tower or lean against it for any kind of work Beware of any kind of projection above the lifting tower like cornices balconies luminous s...

Page 14: ...se the pin is hard to pull out a small number of move ments should be made with the winch until founding the right position where the pin is released and can be pulled out comforta bly Under no circum...

Page 15: ...urer or an authorised distributor within your territory 6 SPECIFIC RISKS Braking system failure May occur due to braking system deficien cies or bad installation If it stops working it could cause a s...

Page 16: ...a different level knocks and or contusions with objects The risk of objects falling to a different level can be prevented by using homologated safety elements e g a safety pin which fixes the inner pr...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20...

Page 21: ...21 NOTAS NOTES LIFTING TOWERS...

Page 22: ...22 NOTAS NOTES LIFTING TOWERS...

Page 23: ...23 NOTAS NOTES LIFTING TOWERS...

Page 24: ...FENIX Stage S L U FENIX Stage S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain Tel 34 96 125 08 55 export fenixstage com www fenixstage com www fenixstage com...

Reviews: