background image

12

12

ENGLISH

1. INTRODUCTION

This instruction manual has been drafted 

in accordance with the requirements of the 

Machinery Directive CE 2006/42/EG. The 

instruction manual is an integral part of the 

lifting tower to be consulted before, during 

and after tower’s start-up, likewise whenever 

deemed necessary, respecting the contents 

for each and all the parts thereof.

This is the only way to achieve the basic ob-

jectives established in the manual’s base such 

as preventing accident risks and the maxi-

mum possible optimisation for the lifting 

tower features.

This manual has taken extreme care regar-

ding safety and accident prevention at work 

while using the machine, highlighting infor-

mation of particular interest to the user.

ATTENTION: BEFORE TO USING THE 

LIFTING TOWER, 

READ THIS MANUAL CAREFULLY

2. GENERAL DATA
2.1. Technical Data:
Name:

 LIFTING TOWER

Model

: NEMESIS PRO

Technical characteristics:

Maximum height: 3,80m.

Minimum height: 1,38m.

Maximum load: 100kg.

Minimum load: 25kg.

Material: Steel EN 10305-5.

Open base area: 1,50 x 1,50m.

Closed base area: 0,17 x 0,17m.

Weight: 26kg.

Winch: 450kg maximum load with automa-

tic load retention brake.

Cable: Galvanized steel under EN 12385-4.  

Cable maximum load: 652kg.

Cable torsion resistance: 1.690 N/mm².

Cable diameter: 3mm.

Cable composition: 7x19+0.

Fixation of tower sections to working height 

with safety pins.

Leg anchorage with safety pins.

Bubble level to adjust tower’s vertical posi-

tion.

Equipment description:

Lifting tower NEMESIS PRO has been desig-

ned to vertically raise structures and lighting 

and sound equipment to different heights.

Tested by skilled personnel having passed all 

the operating, maximum load and dimen-

sion inspections.

Company:

 FENIX Stage, S.L.U. 

Address:

 Avda. de los Trabajadores, 24

Horno de Alcedo - 46026 - Valencia (Spain)

2.2. Applicable regulations

- Machinery Directive CE 2006/42/EG.

- BGV C1 (GUV 6.175).

- BGG 912 (GUV 66.15, GUV G-912).

- EN 12385-4:2008-06.

- DIN EN 10305-3:2010-05.

Summary of Contents for NEMESIS PRO

Page 1: ...l No Instrucciones Instructions LIFTING TOWERS Fabricante Manufacturer FENIX Stage S L U FENIX Stage S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain Tel 34 96 125 08 55 export f...

Page 2: ...2 2 FENIX STAGE S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain NEMESIS PRO Aus hrung 2008...

Page 3: ...bility the conformity of the product Name Model Description to which this declaration refers as per the following regulations CE 2006 42 EG Person empowered to compile the technical file and authorise...

Page 4: ...sions Fecha Date Verificador Verifier Firma Signature Partes comprobadas Tested parts Conclusiones Conclusions Fecha Date Verificador Verifier Firma Signature Partes comprobadas Tested parts Conclusio...

Page 5: ...unto 3 p g 8 seguir las instrucciones de uso ver punto 4 p g 9 un manteniminto peri dico ver punto 5 p g 10 conocer los sistemas de prevenci n ver punto 7 p g 11 BGV C1 is a regulation for staging and...

Page 6: ...E SEGURIDAD 8 4 INSTRUCCIONES DE USO 9 5 MANTENIMIENTO 10 6 RIESGOS ESPEC FICOS 10 7 SISTEMAS DE PREVENCI N 11 INDEX 1 INTRODUCTION 12 2 GENERAL DATA 12 2 1 Technical data 12 2 2 Applicable regulation...

Page 7: ...os Denominaci n TORRE ELEVADORA Modelo NEMESIS PRO Caracter sticas t cnicas Altura m xima 3 80m Altura m nima 1 38m Carga m xima 100kg Carga m nima 25kg Material Acero seg n EN 10305 5 rea de la base...

Page 8: ...po de trabajo Tenga cuidado con todo tipo de salientes por encima de la torre elevadora como cornisas balcones letreros luminosos etc Es muy importante evitar la presencia de cables por debajo de la a...

Page 9: ...de que el gatillo est duro y sea dif cil de sacar hay que realizar un peque o juego con el cabestrante hasta encontrar la posici n exacta donde se libere el gatillo y se pueda sacar c modamen te En ni...

Page 10: ...de su territorio 6 RIESGOS ESPEC FICOS Fallo del sistema de freno Puede producirse por deficiencias en el siste ma de frenado o por una mala instalaci n Si deja de funcionar puede provocar un riesgo...

Page 11: ...las torres de forma segura Sobre ca da de objetos a distinto nivel golpes y o contusiones con objetos El riesgo de ca da de objetos a distinto nivel puede prevenirse con la utilizaci n de elementos d...

Page 12: ...SIS PRO Technical characteristics Maximum height 3 80m Minimum height 1 38m Maximum load 100kg Minimum load 25kg Material Steel EN 10305 5 Open base area 1 50 x 1 50m Closed base area 0 17 x 0 17m Wei...

Page 13: ...r element which might move Never use a ladder over the lifting tower or lean against it for any kind of work Beware of any kind of projection above the lifting tower like cornices balconies luminous s...

Page 14: ...move ments should be made with the winch until founding the right position where the pin is released and can be pulled out comforta bly Under no circumstances any of the pins should be pulled with fo...

Page 15: ...anufacturer or an authorised distributor within your territory 6 SPECIFIC RISKS Braking system failure May occur due to braking system deficien cies or bad installation If it stops working it could ca...

Page 16: ...o a different level knocks and or contusions with objects The risk of objects falling to a different level can be prevented by using homologated safety elements e g a safety pin which fixes the inner...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20 NOTAS NOTES LIFTING TOWERS...

Page 21: ...21 NOTAS NOTES LIFTING TOWERS...

Page 22: ...22 NOTAS NOTES LIFTING TOWERS...

Page 23: ...23 NOTAS NOTES LIFTING TOWERS...

Page 24: ...FENIX Stage S L U FENIX Stage S L U Avda de los Trabajadores 24 Horno de Alcedo 46026 Valencia Spain Tel 34 96 125 08 55 export fenixstage com www fenixstage com www fenixstage com...

Reviews: