background image

                                                                          

EN

                                                                  

Tsense OLED Thermostat

 

 

Installation and User Manual

  

 

The best possible EU ecodesign 2009/125/EC rating (40%). 
EU2015/1188 Information requirements for electric local space heaters: 

With electronic room temperature control plus day timer 

YES

 

With distance control option 

YES

 

With adaptive start control 

YES

 

With open window detection 

YES

 

 

TECHNICAL SPECIFICATIONS

 

Bluetooth:

  

 

Version  4.2 

Power supply:

  

 

230V - 50Hz 

Maximum load:

  

 

16A (resistive) 

Temperature range:

    

+5°C/+35°C 

External Temperature setback:

  

230V - 50Hz 

IP class:

  

 

IP21 

Standard Color:

  

 

White, Black 

Sensors:

  

Built-in room sensor and external floor 
sensor NTC or wireless BLE sensor 

 

INSTALLATION 

Installation must be done by a qualified electrician in accordance with wiring and building 
regulations. Before installation, disconnect any power to the thermostat’s mains.  

 

In a factory new thermostat the front cover (A) and frame (B) are loose and you can just 
pull them out. If the visual parts are fixed then push the rotary dial (C°) hard downwards 
and while holding it down turn anti-clockwise. The front cover and the frame can now be 
pulled away easily.  

 

Connect  the  wires  to  the  thermostat’s  terminal: 

SETBACK:

  External  Setback  Wire  (if 

applicable), 

HEATING (N):

 Heating Cable N connection, 

N:

 Power N connection, 

FLOOR 

SENSOR:

 Floor temp sensor NTC, 

HEATING (L):

 Heating Cable L connection,  

L:

 Power L 

connection. 

 

Next, position the thermostat and fasten it into the wall mounting box using 2-4 screws. 
Assemble the frame. Check that fixing nails are in 'LOCK' position. If not use screwdriver 
to push them to correct position. Push the front cover until it snaps in place. The front 
cover should now be firmly fixed on all sides.  
 

STARTUP 

After connecting the power to the thermostat for the first time thermostat recognizes if 
floor sensor  is connected or  not and  makes initialization accordingly (selects between 
floor mode and air mode). The following settings are initialized accordingly (floor/air). 

Name of thermostat :

   

RANDOM number 

Mode :

  

 

Floor / Air 

Floor temperature min :

  

5°C / NaN 

Floor temperature max :

  

27°C / NaN 

Floor temperature offset (calibration) :

  

-3°C 

Air temperature min : 

  

5°C 

Air temperature max :

  

28°C 

Air temperature offset (calibration) :

  

0°C 

PWM min – PWM max :

  

0% - 100% 

Snow melting ON temperature min :  

0°C 

Snow melting ON temperature max :  

10°C 

Snow melting OFF temperature:  

-25°C 

Snow melting air humidity min:  

30%

 

User program activated eco temp :

  

19°C  

Externally activated eco temp :

  

19°C

  

Valve protection :

  

 

OFF 

Sensor type :

  

 

10k ohm 

Display brightness in standby:

  

70% 

Weekly program

 :  

 

OFF 

Use ecoControl App to check and modify settings. 

BASIC USE 

The thermostat is controlled by rotary dial (C°) and a touch button (SET). The basic use of 
thermostat is described in picture END USER FUNCTIONS: 

1.

 Normal mode with dim screen saver display. Use rotary dial to step into active mode 

(2). 

2.

 Active mode. Rotating the dial takes you to modify the set temperature of a current 

operating  state (3). Touching the set button enters the menu (4).  

3.

  Adjust  the  temperature  set  value  of  the  current  state  (comfort,  eco  or  externally 

activated setback eco). Return to the start by touching the set button or automatically 
after a timeout period. 

Notice

 that in set value page current operating state is shown under the set temperature 

digits. A flash symbol is indicating the relay activity. 

4.

 In menu you can step from function to function with the rotary dial and then enter the 

function by touching the set button: 
- touch the set button to select comfort state and adjust the temperature set value with 
rotary dial. Return back to start by touching the set button.  
- select eco mode by touching the set button and adjust with rotary dial the set point of 
user program eco temperature or the setback eco temperature (if setback input active). 
Return to the start by touching the set button. 
- display the current heating mode 
- select BOOST 1h to force a thermostat to use a special temperature for 1 hour 

- switch off the power by touching the set button. Power is switched on by rotating the 
dial. 
- display the link to user manuals (QR-code link) 
- from EXIT you return to the start by touching the set button. 
 

ADVANCED USE 

You can access all the thermostat data with a free of charge ecoControl App running in 
Android and iOS mobile devices. With the App you read logged temperatures, modify 
settings and define a weekly user program. App can also generate email reports. Follow 
the guides in ecoControl App. Thermostat indicates the mobile device connection with 
fast blinking red led. 

1.

 

Settings 

Thermostat has several settings which can easily be adjusted with ecoControl App. Note! 
Remember to save changes before leaving the setting page. 

Name of thermostat 

A free and descriptive name shown in ecoControl App 

Heating mode 

Thermostat can measure and adjust 

floor

 temperature, 

air

 temperature, air temperature 

with floor limits (

dual

), heating ratio (

PWM

 control) or it can melt snow and ice from 

outdoor stairs and driveways in 

snow melting

 mode.   

Floor temperature min and max 

This setting  has two  main  purposes. In floor mode  min and max values  specify active 
range of knob. In dual mode this setting does not effect the knob but thermostat keeps 
floor temperature between limits. Feature can be used to protect wooden floors (max 
limit) or e.g. to guarantee warm floor in room with fireplace. Note: N/A in PWM and in 
air mode. 

Floor temperature offset (calibration) 

If  user's  temperature  measurement  has offset to  knob  setpoint  this  setting  is used to 
calibrate. 

Note,  floor  sensor  inside  floor  construction  is  much  warmer  than  real 

temperatures measured in room. Thus default is -3C to have rotary knob adjustment 
range in realistic area of 18C...24C.

  

Air temperature min and max

 

This setting has two main purposes. In air and dual mode it specifies active knob range. 
In all other modes it can be used as air over temperature protection. 

Air temperature offset (calibration) 

If  user's  temperature  measurement  has offset to  knob  setpoint  this  setting  is used to 
calibrate.

 

PWM min and max 

This setting has two main purposes. In PWM mode min and max values specify active 
knob range. In all other modes it guarantees maximum pulse ratio. Note: Setting can be 
used,  e.g.,  to  limit  maximum  heating  power  to  comply  with  installation  standard 
EN50599. Cycle time of PWM is 10 minutes.  

Snow melting ON temperature min and max 

Min and max setting specify the active knob range. When outdoor temperature is below 
this setting point the snow melting operation is active.

 

Snow melting OFF temperature 

When it is colder than this temperature the snow melting is switched OFF.  

Snow melting air humidity min 

When  wireless  outdoor  temperature  sensor  is  used  the  thermostat  also  receives  air 
humidity level. Snow melting function will not be activated if the air humidity is below 
this limit.

 

User program activated eco temp 

During all green hours in user program the temperature is adjusted to this value. In PWM 
mode, the pulse ratio in eco mode is half of the pulse ratio in comfort mode. In snow 
melting, eco mode switches off the heating completely.  

Externally activated eco temp 

When 230VAC (pilot signal) is connected to the setback input terminal the temperature 
set value is defined by this parameter. 

Valve protection 

Valve protection turns heating ON once per week for 5 minutes even at summer time. 
This setting is typically used with water carrier floor heating valves. Feature prevents the 
valve from getting stuck during summer. 

 

Sensor type 

Floor sensors from different manufacturers can be used. Supported types are 2k, 10k, 
12.5k, 15k, 33k NTCs. 

Display brightness  

Brightness of the Oled display in standby mode. 

User program mode 

AUTO enables the user program, OFF disables it. 

Wireless temperature sensor 

Adding  a  wireless  BLE  temperature  sensor  allows  the  best  location  for  temperature 
measurement. It is also very accurate. To add a wireless sensor you have to select it in 
the ecoControl App and enter the sensor address in Network key fields. 

Receive wireless eco controls 

A thermostat with an external setback switch can control several other thermostats to go 
in setback mode. This feature will save the user from hard wiring the Home/Away switch 
to many thermostats. To form a group of thermostats you need to enable the 

Receive 

wireless eco controls

 and write a freely selectable group name in 

Network key

 fields. 

Network key and Confirm Network key 

Network  key  is  used  to  identify  the  wireless  temperature  sensor  or  the  group  of 
thermostats to receive  the wireless eco controls. Both fields need to have exactly the 
same text string and you have to save the settings. For the wireless sensor you can use 
the QR code (back side of the device or inside of the cover part). Just use the camera 
function in App (bottom of the screen) to read the code, then accept and save it. 

Lock function 

The thermostat display can be locked and unlocked with the app. Use PIN code 0914. 

Summary of Contents for Tsense

Page 1: ...e OLED Bluetooth Thermostat 230V 16A IP21 www taelek fi documents VIDEOS AND MANUALS App Store Google Play and Homey are trademarks of Apple Google and Athom in respectively EN DE CZ SK FR PL ES RU N873 R00 14 01 22 ...

Page 2: ... also generate email reports Follow the guides in ecoControl App Thermostat indicates the mobile device connection with fast blinking red led 1 Settings Thermostat has several settings which can easily be adjusted with ecoControl App Note Remember to save changes before leaving the setting page Name of thermostat A free and descriptive name shown in ecoControl App Heating mode Thermostat can measu...

Page 3: ...iches Programm AUS Nutzen Sie die ecoControl App um die Einstellungen zu überprüfen und zu ändern GRUNDLEGENDE VERWENDUNG Das Thermostat wird über einen Drehknopf C und eine Touch Taste SET gesteuert Die grundlegende Verwendung des Thermostats ist im Bild ENDBENUTZERFUNKTIONEN beschrieben 1 Normaler Modus mit abgedunkelter Bildschirmschoneranzeige Verwenden Sie das Drehrad um in den aktiven Modus ...

Page 4: ... zurückzusetzen indem Sie den Strom abschalten und einen Soft Reset durchführen oder Sie können mit der ecoControl App einen harten Reset durchführen Bei den Fehlern 1 2 3 ist die heizung dauerhaft aus Bei Fehler 10 ist das Anwenderprogramm deaktiviert GEWÄHRLEISTUNG UND HAFTUNG Der Verkäufer garantiert für einen Zeitraum von zwei Jahren dass dieses Produkt frei von Herstellungs Material und Verar...

Page 5: ...ontrol a zadání adresy čidla do kolonky Klíč sítě Přijmout bezdrátové ovládání útlumové teploty Termostat jehož útlum je řízen pilotním vodičem může bezdrátově přepnout do útlumu i další termostaty Tato funkce ulehčí od nutnosti přivést pilotní vodič ke každému z termostatů K vytvoření skupiny termostatu je třeba aktivovat funkci Přejmout bezdrátové ovládání teploty a zapsat název skupiny do políč...

Page 6: ...u má dve hlavné funkcie PWM určuje hodnotu rozsahu nastaviteľnú otočným kolieskom V ostatných režimoch zaisťuje pomer pulznej šírkovej modulácie Dĺžka cyklu PWM je 10 minút Požadovaná teplota protimrazovej ochrany Nastavenie určuje aktívny rozsah nastaviteľný otočným kolieskom Pokiaľ vonkajšia teplota spadne pod nastavenú teplotu spustí sa rozmrazovanie Minimálna teplota pre protimrazovú ochranu P...

Page 7: ...cation mobile ecoControl ATTENTION N oubliez pas d enregistrer les modifications avant de fermer l application Nom du thermostat Le nom du thermostat défini par l utilisateur qui peut être utilisé pour identifier l appareil dans l application mobile Mode Le thermostat peut mesurer et réguler la température du sol plancher la température d ambiance ambiance la température d ambiance avec des limite...

Page 8: ...a 0 C PWM min PWM max 0 100 Topienie śniegu ON przy min temperaturze 0 C Topienie śniegu ON przy max temperaturze 10 C Topienie śniegu OFF przy temperaturze 25 C Wilgotność powietrza przy topieniu śniegu min 30 Temp ECO aktywowana programem 19 C Temp ECO aktywowana zewnętrznie 19 C Ochrona zaworu OFF Typ czujnika 10k ohm Jasność wyświetlacza w trybie czuwania 70 Program tygodniowy OFF Użyj aplikac...

Page 9: ... napięcia zasilającego wynosi 2h 3 Rodzaje błędów Najczęstszą przyczyną błędu jest niewłaściwa wartość czasu rzeczywistego co powodowane jest zbyt długą przerwą w zasilaniu Problem ten jest automatycznie rozwiązywany po połączeniu z aplikacją ecoControl Stosując aplikację ecoControl można odczytać kod błędu Możliwe są następujące kody 1 Błąd czujnika podłogowego Ogrzewanie WYŁĄCZONE 2 Przegrzanie ...

Page 10: ...peratura exterior caiga bajo la temperatura ajustada se inicia la fundición de nieve Temperatura apagado modo fundir nieve En caso de que la temperatura exterior sea más baja que la temperatura programada la fundición de nieve se desconecta Humedad realativa aire mínima modo fundir nieve En caso de utilizar el sensor exterior inalámbrico el termóstato recibe también informaciones sobre la humedad ...

Page 11: ...ройства с помощью быстро мигающего красного светодиода 1 Настройки Термостат имеет несколько настроек которые можно легко отрегулировать с помощью приложения ecoControl App Примечание Не забудьте сохранить изменения прежде чем покинуть страницу настроек Название термостата Свободное и описательное имя отображаемое в приложении ecoControl App Режим обогрева Термостат может измерять и регулировать т...

Page 12: ...ому устройству Часы реального времени могут управлять перерывами в подаче электроэнергии до 2 часов 3 Режимы ошибок Термостат указывает на некорректное состояние отображая текст ERROR и код ошибки Наиболее типичным случаем является нарушение реального времени во время слишком длительного перерыва в подаче электроэнергии Это автоматически решается при подключении к приложению ecoControl Возможные к...

Reviews: