background image

Fenwal Controls 
400 Main Street 
Ashland, MA  01721 
Tel. (508) 881-2000  

© 

Kidde-Fenwal Inc.   06-237657-001 

 Rev A

C

 

EU DECLARATION OF CONFORMITY 

We 

Company Name: 

 

Kidde-Fenwal Inc. 

Postal Address: 

400 Main Street 

City and Post Code:  

Ashland, MA 01721 

Tel:   

508-881-2000 

Declare that the DoC is issued under sole responsibility and belongs to the following product: 

Apparatus Model(s) 

Series 35-40, 35-53, 35-60, 35-61, 35-63, 35-608, 35-65, 35-66, 35-9X 

Type: 

Fitting 

Batch Number  

Date code and Revision Level Assigned per production lot, (YYWW RR) 

Object of the Declaration: 

Series 35-40, 12/24Vdc Direct Spark Automatic Gas Ignition Controllers 
Series 35-53, 12Vdc Direct Spark Automatic Gas Ignition Controllers 
Series 35-60, 35-61, 35-63, 35-608 24Vac Direct Spark Automatic Gas Ignition 
Series 35-65 & 35-66 24Vac Hot Surface Automatic Gas Ignition Controllers 
Series 35-9X Platform Ignition Module

SERIES 35-40 

SERIES 35-53 

SERIES 35-60/61/63/608 

SERIES 35-65/66 

SERIES 35-9X 

The object of the declaration described above is in conformity within the relevant union 
harmonization legislation: 

Gas Appliance Regulation

(

EU) 2016/426 

Low Voltage Directive: 

2014/35/EC 

EMC Directive:

2014/30/EC

Rohs 

2011/65/EU

The following harmonized standards and technical specifications have been applied: 

EN298:2012:    

Automatic Burner Control systems for Burners and appliances burning gaseous or liquid fuels. 

EN13611:2007_A2:2011: 

Safety and control devices for Gas Burners and Gas burning appliances – General Requirements. 

Name of Notified Body & Number: 

BSI Group, 0086, EU Type Examination Certification 

Notified Body Certificate No.: 

Series 35-40:   

CE682407 

Series 35-53   

CE682404 

Series 35-60/61/63/608 

CE682405 

Series 35-65/66 

CE682406 

Series 35-9x   

CE

690652

 

Surveillance Audit Notified Body: 

BSI Group 

For copies of the Installation Instructions and the EU DoC, got to 

www.fenwalcontrols.com

, - Document Library - Data sheets. 

Paul Finn 

Kidde-Fenwal, Inc. Ashland, MA USA 

01

 

Oct

 2018 

Paul Finn, Certification Engineer 

Place of Issue:  

Date of Issue 

Name 

Summary of Contents for 35-608 Series

Page 1: ...nterpurge time on CE approved models Certification varies by model EMC emission requirements shall be verified after incorporation of the burner control system into the end use appliance CSA Design certified to ANSI Z21 20 CAN CSA C22 2 No 199 M99 SPECIFICATIONS Input Power Control 18 30 VAC 50 60 Hz 8W Class 2 Transformer Input Current Drain 300 mA 24 VAC with gas valve relay energized Control on...

Page 2: ...t be done by qualified service technician WARNING Operation outside specifications could result in failure of the Fenwal product and other equip ment with injury to people and property 6 Pin Standard 35 608 Model 156 Header Name Description Connection MV Main Gas Valve Pin 1 TH Thermostat Pin 2 GND Ground Pin 3 GND Ground Pin 4 LAMP NC Normally Closed Pin 5 S1 Flame Sense Pin 6 6 Pin 35 6084 Model...

Page 3: ...ting of 250V and an insulation rating of 200 C Recommended length of 10ft 3m or less Consult Factory for longer lengths Remote Sense BUR NER 1 4 5 2 3 2 CONTACTS H V GND GAS VALVE TH VALVE 24 VAC 6 VALVE GND RESET NC S1 Local Sense BUR NER 1 4 5 2 3 2 CONTACTS H V GND GAS VALVE TH VALVE 24 VAC 6 VALVE GND RESET NC S1 FL AM E SENSOR Local Sense BUR NER 1 2 5 6 3 4 FC 2 CONTACTS FC H V GND GND GAS V...

Page 4: ...ITION MODE STANDARD If the established flame signal is lost while the burner is operat ing the control will respond within 0 8 seconds max by ener gizing the HV spark for the programmed TFI period in an attempt to relight the burner If the burner does not light within the TFI the gas valve is de energized immediately and on multi try models a new TFI sequence begins If the burner does not relight ...

Page 5: ...oper location of the electrode assembly is important for optimal system performance The electrode assembly should be located so that the tips are inside the flame envelope and about 1 2 inch 1 2 cm above the base of the flame Ceramic insulators should not be in or close to the flame Electrode assemblies should not be adjusted or disassem bled Electrodes should have a gap spacing of 0 125 0 031 inc...

Page 6: ...mensions TH VALVE GND GND VALVE NC 1 750 MAX 2 50 MAX 3 940 910 5 200 3 380 283 3 375 RED LED 187 010 DIA 4 MOUNTING HOLES GREEN LED REMOTE FLAME SENSE TERMINAL FC FC 5 or 6 PIN HEADER 1 750 MAX 2 15 MAX 3 940 910 5 200 3 380 283 3 375 PIN 1 RED LED 8 PIN HEADER 187 010 DIA 4 MOUNTING HOLES GREEN LED 250 Q C MALE XX SEC 1 56 SPACING ...

Page 7: ... 1 Single Try Remote Sense 2 Single Try Local Sense with 1 Hour Automatic Reset 3 Single Try Remote Sense with 1 Hour Automatic Reset 5 Three Tries Local Sense 6 Three Tries Remote Sense 7 Three Tries Local Sense with 1 Hour Automatic Reset 8 Three Tries Remote Sense with 1 Hour Automatic Reset PRE PURGE 0 None 1 15 Seconds 2 30 Seconds INTER PURGE 0 None 1 15 Seconds 2 30 Seconds TRIAL FOR IGNITI...

Page 8: ...3 SERIES 35 60 61 63 608 SERIES 35 65 66 SERIES 35 9X The object of the declaration described above is in conformity within the relevant union harmonization legislation Gas Appliance Regulation EU 2016 426 Low Voltage Directive 2014 35 EC EMC Directive 2014 30 EC Rohs 2011 65 EU The following harmonized standards and technical specifications have been applied EN298 2012 Automatic Burner Control sy...

Reviews: