background image

THE TOTAL SOLUTION FOR 

GAS IGNITION CONTROL

Fenwal offers a complete range of ignition 
control including: 

n

Ignition Controls

n

Spark and Flame Sense Electrodes

n

Spark and Flame Sense Cables 

n

Wiring harnesses

Designed, developed and manufactured by Fenwal, these components
integrate seamlessly providing maximum system performance.

Getting Started - Samples

To ensure proper system design and operation, Fenwal provides 
sample ignition controls, high-voltage wires and electrodes  for trial 
and evaluation at no charge.  To get you started quickly, Fenwal has 
identified our most popular ignition controls, see Page 8.  Whether 
it is an individual control,  complete start-up kit or customized control, 
Fenwal is ready to provide your gas ignition solution.

Fenwal Ignition Development Center

Send your equipment to us and we’ll design, install and qualify a 
control to meet your exact application requirements.  Fully equipped 
and staffed with trained technicians, the Fenwal Ignition Development
Center has proven extremely beneficial for many customers focused on
product quality and reducing time-to-market for their appliances.

FEATURES

n

3 Enclosure Configurations

n

Case and Cover - dust and foreign object protection

n

Open Board with Stand-Off's - saves space and cost 

n

Potted - protection for washdown and extreme vibration

n

2 Wiring Options – ¼” quick connects and multi-pin connector

n

2 Trial for Ignition Options – 1 and 3 try

n

4 Trial for Ignition Times – 4, 7,10 and 15 seconds 

(customized timings available)

n

2 Flame Sense Options – 

single spark and sense and remote sense

n

2 Reset Options – thermostat/power off and automatic  

(1 hour reset) 

n

Diagnostic LED – 3 error codes for accurate troubleshooting

n

Flame Current Test Pins – instant access to circuit 

for troubleshooting

n

Polarity Insensitive – reduces chance of miswiring

APPLICATIONS

n

C

onstruction and Agriculture Heaters

n

Crop Dryers

n

Ceramic and Black Body Infrared Heaters

n

Commercial Cooking Equipment

n

Any 120 VAC Gas Burner Application under 400K BTU

The 35-70 is a 120 VAC direct spark ignition control 
for controlling a gas valve and igniting LP or natural 
gas fired equipment and gas burner applications that 
provide a 120 VAC operating signal.

The microprocessor circuit design provides precise, 
repeatable timing sequences for ignition times and 
purge times (pre- and inter-) as well as multiple tries 
for ignition, one hour automatic reset and flame sensing 
during pre-purge.  The on-board diagnostics with LED 
output provide assistance with trouble-shooting to 
ensure safe and efficient burner operation.

Agency Certifications

Recognized under the Component Program of Underwriters
Laboratories Inc., UL 372, UL 1998 Software

Design certified by CSA International, CAN C22.2 #199-M89 
and ANSI Z21.20 Automatic Ignition Systems

FM Approved as both an ignition device and a flame safeguard.
Restricted to single try models without 1 hour reset.  
TFI time must be 15 seconds or less.  

35.70.02

Series 35-70, 120 VAC Direct Spark Ignition Control

Page 1

www.fenwalcontrols.com

1-800-FENWAL-1

SERIES 35-70

120 VAC Microprocessor Based
Direct Spark Ignition Control

®

StockCheck.com

Downloaded from StockCheck.com

Summary of Contents for 35-70 Series

Page 1: ...ized timings available n 2 Flame Sense Options single spark and sense and remote sense n 2 Reset Options thermostat power off and automatic 1 hour reset n Diagnostic LED 3 error codes for accurate troubleshooting n Flame Current Test Pins instant access to circuit for troubleshooting n Polarity Insensitive reduces chance of miswiring APPLICATIONS n Construction and Agriculture Heaters n Crop Dryer...

Page 2: ...tion attempt the inter purge sequence is completed between the next two attempts to re light the burner If the burner fails to light after the third attempt the control will de energize the gas valve and go into lockout mode RECYCLE If the established flame signal is lost the control responds by shutting off the gas valve within 0 8 seconds SINGLE TRIAL MODEL The control will begin the ignition cy...

Page 3: ...ty transformer on control E Faulty control consult Fenwal A Shorted electrode re establish 1 8 gap B High voltage cable is disconnected C Check wiring A Valve coil open B Valve wire disconnected C Faulty control check voltage V1 A Check electrode position B Check high voltage wire and connection C Poor ground burner D Check flame current E Check flame current on control SINGLE SPARK AND SENSE REMO...

Page 4: ...ssing from ground through the flame to the sense rod The minimum flame current necessary to keep the system operating is 1 0 DC microamperes SINGLE SPARK AND SENSE Figure 3a REMOTE FLAME SENSE Figure 3b ITEM 1 2 3 4 5 6 7 8 9 DESCRIPTION Mounting Bracket 1 4 Q C HighVoltageTerminal 3 16 Q C FlameSenseTerminal Spark H V Ceramic Tube Sense Electrode Ceramic Tube Press Ring Flame Sense Electrode Grou...

Page 5: ...trode styles available These electrodes are designed for on site customization Cut and bend these to fit your application and then send the formed electrode back for Fenwal to detail or send us a print and we will provide you with a quote and samples Part Number 22 100000 593 Part Number 22 100001 076 Part Number 22 100001 117 Part Number 22 100001 052 SPARK ELECTRODE WITH INTEGRAL REMOTE FLAME SE...

Page 6: ...elect the proper harness based on flame sense option Once the terminal configuration is determined complete the part number by replac ing the last two digits XX with the length in inches L dimension Standard wire lengths are 12 18 24 30 36 48 and 60 inches Example 05 129864 518 18 inches For other lengths please contact Fenwal SPECIFICATIONS Voltage Rating Agency Rating Temperature Rating Diameter...

Page 7: ...ger than 36 Longer lengths are available and should be evaluated on the appliance to determine if there is sufficient spark energy to consistently light the burner under all conditions Once the wire type and terminal configurations are determined complete the part number by replacing the last two digits XX with the length in inches L dimension Standard wire lengths are 12 18 24 30 36 48 and 60 inc...

Page 8: ...ry remote sense Thermostat power off reset 2 1 try single spark and sense Automatic reset 3 1 try remote sense Automatic reset 5 3 try single spark and sense Thermostat power off reset 6 3 try remote sense Thermostat power off reset 7 3 try single spark and sense Automatic reset 8 3 try remote sense Automatic reset X 0 X 35 70 5 X X X 400 MAIN STREET ASHLAND MA 01721 TEL 508 881 2000 FAX 508 881 6...

Reviews: