Electrode Assemblies

continued

REMOTE SENSE

Part Number: 05-129864-6XX

Part Number: 05-129864-5XX

Part Number: 22-100001-110

Part Number: 05-129864-0XX

Part Number: 05-129864-1XX

SINGLE SPARK AND SENSE

REMOTE FLAME SENSE ROD

To make your own harness select AMP connector housing P/N: 1-770849-1 and AMP housing terminal P/N: 770522-1

1/4” FEMALE Q.C.  -
FULLY INSULATED

To make your own harness select AMP connector housing P/N: 1-770849-1 and AMP housing terminal P/N: 770522-1

1/4” FEMALE Q.C.  -
FULLY INSULATED

Control Wire Harness

Select the proper harness based on flame sense option.   Once the terminal configuration is determined, complete the part number by replac-
ing the last two digits (“XX”) with the length in inches (“L” dimension).  Standard wire lengths are 12, 18, 24, 30, 36, 48, and 60 inches.
Example: 05-129864-518 = 18 inches.  For other lengths, please contact Fenwal.  

SPECIFICATIONS: Voltage Rating

Agency Rating

Temperature Rating

Diameter

Jacket Material

All Wires

600  V

UL/CSA Listed

105°C (221°F)

18 gage stranded

PVC

Gray Only

600  V

UL/CSA Listed

200°C (392°F)

18 gage stranded

PVC

Page 6

Series 35-70, 120 VAC Direct Spark Ignition Control

www.fenwalcontrols.com

1-800-FENWAL-1

“L”

“L”

“L”

“L”

Part Number: 22-100001-080

StockCheck.com

Downloaded from StockCheck.com

Summary of Contents for 35-70 Series

Page 1: ...ized timings available n 2 Flame Sense Options single spark and sense and remote sense n 2 Reset Options thermostat power off and automatic 1 hour reset n Diagnostic LED 3 error codes for accurate troubleshooting n Flame Current Test Pins instant access to circuit for troubleshooting n Polarity Insensitive reduces chance of miswiring APPLICATIONS n Construction and Agriculture Heaters n Crop Dryer...

Page 2: ...tion attempt the inter purge sequence is completed between the next two attempts to re light the burner If the burner fails to light after the third attempt the control will de energize the gas valve and go into lockout mode RECYCLE If the established flame signal is lost the control responds by shutting off the gas valve within 0 8 seconds SINGLE TRIAL MODEL The control will begin the ignition cy...

Page 3: ...ty transformer on control E Faulty control consult Fenwal A Shorted electrode re establish 1 8 gap B High voltage cable is disconnected C Check wiring A Valve coil open B Valve wire disconnected C Faulty control check voltage V1 A Check electrode position B Check high voltage wire and connection C Poor ground burner D Check flame current E Check flame current on control SINGLE SPARK AND SENSE REMO...

Page 4: ...ssing from ground through the flame to the sense rod The minimum flame current necessary to keep the system operating is 1 0 DC microamperes SINGLE SPARK AND SENSE Figure 3a REMOTE FLAME SENSE Figure 3b ITEM 1 2 3 4 5 6 7 8 9 DESCRIPTION Mounting Bracket 1 4 Q C HighVoltageTerminal 3 16 Q C FlameSenseTerminal Spark H V Ceramic Tube Sense Electrode Ceramic Tube Press Ring Flame Sense Electrode Grou...

Page 5: ...trode styles available These electrodes are designed for on site customization Cut and bend these to fit your application and then send the formed electrode back for Fenwal to detail or send us a print and we will provide you with a quote and samples Part Number 22 100000 593 Part Number 22 100001 076 Part Number 22 100001 117 Part Number 22 100001 052 SPARK ELECTRODE WITH INTEGRAL REMOTE FLAME SE...

Page 6: ...elect the proper harness based on flame sense option Once the terminal configuration is determined complete the part number by replac ing the last two digits XX with the length in inches L dimension Standard wire lengths are 12 18 24 30 36 48 and 60 inches Example 05 129864 518 18 inches For other lengths please contact Fenwal SPECIFICATIONS Voltage Rating Agency Rating Temperature Rating Diameter...

Page 7: ...ger than 36 Longer lengths are available and should be evaluated on the appliance to determine if there is sufficient spark energy to consistently light the burner under all conditions Once the wire type and terminal configurations are determined complete the part number by replacing the last two digits XX with the length in inches L dimension Standard wire lengths are 12 18 24 30 36 48 and 60 inc...

Page 8: ...ry remote sense Thermostat power off reset 2 1 try single spark and sense Automatic reset 3 1 try remote sense Automatic reset 5 3 try single spark and sense Thermostat power off reset 6 3 try remote sense Thermostat power off reset 7 3 try single spark and sense Automatic reset 8 3 try remote sense Automatic reset X 0 X 35 70 5 X X X 400 MAIN STREET ASHLAND MA 01721 TEL 508 881 2000 FAX 508 881 6...

Reviews: