These screws must not be adjusted. The position of
these screws may only be altered by the
manufacturer!
Check regularly if the clamping screws are
tightened firmly. Always tighten screws firmly.
CORRECTIVE ACTION IN CASE OF
FAILURE
1. The operating switch is switched on, but the
motor is not working.
-
The electric circuit is broken.
Have the electric circuit repaired.
-
Wires in the mains plug or in the socket are loose.
Have socket and plug checked or repaired.
-
The switch is faulty.
Have the switch replaced.
2. The operating switch is switched on, but
unusual noises can be heard, the motor is not
working or only very slowly.
-
Switch contact has fused.
Have the switch replaced.
-
Component jammed.
Have the electric tool checked or repaired.
-
Too much thrust, as a result the motor is dragging.
Use less thrust during the task.
3. Motor gets hot.
-
Foreign substances have got inside the motor.
Have the foreign substances removed.
-
Lack of or contaminated lubricating grease.
Have lubricating grease applied or replaced.
-
Pressure too high.
Use less thrust during the task
-
Planing tool blunt.
Replace the planing tool.
4. The motor is working, but the planing tool is
not moving.
-
V-belt worn.
Have V-belt replaced.
5. Frequent or strong sparks on the
commutator.
-
Short circuit on the armature.
Have the armature replaced.
-
Carbon brushes worn out or jammed
Have the carbon brushes checked.
-
Rough running of the commutator.
Have the surface of the commutator cleaned or
ground
For your own safety, never remove parts or accessories
of the electric tool during operation. In case of fault or
damage have the electric tool repaired only by a
specialist workshop or by the manufacturer.
CAUTION!
Use only original spare parts and original plane blades!
MAINTENANCE
Make sure that the machine is not live when
carrying out maintenance work on the motor.
These appliances are designed to function without
difficulty for a long time and to require minimum
maintenance. You will prolong the appliance's life by
cleaning it regularly and using it correctly.
Cleaning
Clean the housing regularly with a soft cloth, preferably
every time it is used. Keep the air vents free of dust and
dirt.
Remove stubborn dirt with a soft rag moistened in soapy
water. Do not use any solvents such as petrol, alcohol,
ammonia, etc. as such substances can damage the plastic
parts.
Lubrication
The appliance does not need any extra lubrication.
Faults
If a fault arises through wear in an element, please
contact the service address shown on the warranty card.
A drawing of the spare parts that may be obtained is
included at the end of these operating instructions.
ENVIRONMENT
To prevent damage during transport, the appliance is
delivered in a solid packaging which consists largely of
reusable material. Therefore please make use of options
for recycling the packaging.
WARRANTY
Read the terms of warranty on the separate warranty
card which is enclosed.
Please contact the Ferm service address if you have any
questions regarding accessories and/or batteries.
We take sole responsibility for confirming that
this product conforms with the following standards
or related documents:
EN50144-2-14, EN50144-1
EN55014-1, EN55014-2
EN61000-3-2, EN61000-3-3
in accordance with the regulations:
98/37/EEC
73/23/EEC
89/336/EEC
01-07-2004
ZWOLLE NL
W. Kamphof
Quality department
CE
ı
DECLARATION OF CONFORMITY
(UK)
Ferm
5
64
Ferm