Ferm
5
GB
Do not expose to rain
Outdoor noise
Risk of high temperature
Caution: the generator contains
some parts which might reach high
temperatures
Faulty and/or discarded electrical or
electronic apparatus have to be
collected at the appropriate recycling
locations.
Safety instructions
Persons
• Never allow children or people unfamiliar
with these instructions to use the appliance.
Local regulations may restrict the age of the
operator.
• Always operate outdoors with good
ventilation. Exhaust gas contains poisonous
carbon monoxide.
• Always stop the engine before refilling the
fuel tank and clean the machine after filling
the fuel tank.
• Do not inhale fumes from petrol.
Electricity
• Do not touch the generator if you have wet
hands.
• Do not operate the generator in wet
conditions.
• Do not operate the generator near water.
• Never connect two generators together.
• Never connect the generator to any
commercial power outlet.
• Make sure any extension cords used are in
a safe condition and of sufficient capacity
for the task.
• Ensure that the load on the generator falls
within its capacity as specified in the table
before plugging in any cords.
Fire and burn hazards
• The exhaust system gets hot enough to
ignite some materials:
- keep the generator at least 1 meter
away from buildings and other
equipment during operation.
- keep flammable materials away from
the generator.
• The exhaust becomes very hot during
operations and remains hot for a while after
stopping the engine:
- Let the engine cool before storing the
generator indoors.
- Do not touch the hot exhaust with your
hands.
• Gasoline is extremely flammable and is
explosive under certain conditions. Do not
smoke or allow flames or sparks where the
generator is refueled or where gasoline is
stored.
• Fuel vapors are extremely flammable and
may ignite after the engine has started.
Make sure that any spilled fuel has been
wiped up before starting the generator.
• Never shade the generator with clothes or
other articles.
3. Use
Before starting the generator
Ground terminal The generator ground
terminal is connected to the frame of
the generator, the metal non-current-
carrying parts of the generator, and
the ground terminals of each
receptacle. Before using the ground
terminal, consult a qualified electrician,
electrical inspector or local agency
having jurisdiction for local codes or
ordinances that apply to the intended
use of the generator.
Assembly
Unscrew the tank cover. Remove the measuring
jug and fit it into the recess on the bottom of
the tank cover. Screw the tank cover back onto
the tank. Use the enclosed screws to fasten the
carry handle onto the tank.
Important!
Before use, the tank needs to be
filled up with a petrol mixture in a mixing ratio of
50:1. Refer to the table below.
Use the measuring jug inside the tank. One
increment equals 20ml. Mix the mixture well.
Mixture 50:1
Regular unleaded petrol
2 stroke oil
1l
20ml