4

ECC+ 230 V Electronic Module

5 / 6 / 7 

POWER INPUTS 230 VOLTS SINGLE PHASE AC.

 

The circuit has been designed to operate on a mains supply of 230 V AC (+10%,-15%, 50 

or 60 Hz).

 

 

CONTROLS INPUTS

 

The circuit can work with external voltage inputs or by means a volt free contact input.

Open signal.

 

This signal orders the door to open. The voltage required can be from 24 V DC to 60 V DC 

or 100 V AC to 230 V AC with an external supply between this input and common (10).

0 V.

 

Opposite pole to Out 24 V (11). In the case of using internal voltage it should be connected 

to the common input (10).

10 

Common.

 

This input is the reference used for the open and close inputs.

11 

Out 24 V.

 

 

            Isolated 24 V output available to control the door via a voltage free contact. Features are: 

 

 

    

 

a) This supply must only be used for this purpose.

 

 

 

 

b) This contact must be isolated from any other power supply.

12 

Close signal.

 

This signal is used for ordering to close the door.

13 / 14

 

Floor level.

 

This input activates the open movement in emergency rescue mode in case of power 

failure. A 12 V battery is used to rescue the passengers from the lift. The door only will 

open if this signal is bridged (Normally Open).

15 / 16  / 17  

Battery.

 

This input is for connecting a 12 V battery 2,2 Ah to act as external emergency power 

supply and allows the opening movement of the door in case of power failure.

PROGRAMING

 INPUTS

Open

Close

Voltage

 

OPEN

Voltage

 

CLOSE

Open

Close

OPEN

CLOSE

EXTERNAL VOLTAGE INPUT

VOLT FREE CONTACT INPUT

8

9

10

11

12

8

9

10

11

12

24...230 V

24...230 V

Open

Close

Without Voltage

OPEN

With Voltage

CLOSE

Open

Close

Voltage

OPEN

Voltage

CLOSE

1 INPUT

2 INPUTS

Com

12 V

0 V

8

9

10

11

12

Com

12 V

0 V

8

9

10

11

12

24...230 V

24...230 V

24...230 V

24...230 V

Summary of Contents for ECC+ 230 V

Page 1: ...MAN MUED00000ENGTC 12 2017 ENG User manual Automatic horizontal sliding car door Component ECC 230 V Electronic Module...

Page 2: ...WITCH CONTACTO SEGURIDAD SAFETY SWITCH REABRIR 2 REOPEN 2 REABRIR 1 REOPEN 1 SE AL DE PISO FLOOR LEVEL F C CERRAR CLOSE L S CON ENCODER WITH ENCODER ABIERTA CERRADA OPEN CLOSED OK STATUS SPECIAL ESPEC...

Page 3: ...FCE ON Heavy door The motor supplies a 30 extra torque to be able to move heavy doors OFF Standard door Standard control is applied to perform the door movement 4 Floor level Inputs 12 V battery ON 2...

Page 4: ...This supply must only be used for this purpose b This contact must be isolated from any other power supply 12 Close signal This signal is used for ordering to close the door 13 14 Floor level This inp...

Page 5: ...D lit constantly on LED blinking iso phase on and off with a frequency of approximately 5 Hz on for approximately 100 ms followed by off for approximately 100 ms LED single flash one short flash appro...

Page 6: ...a power stage with a current limiting protection The 24 V DC motor incorporates a thermal protection in order to inform the lift controller in case of motor overheating Once the thermal protection is...

Page 7: ...signal is necessary to check that the car door s is are in the closed position To comply with this point an additional door contact is added and the signal has to be connected to the lift controller T...

Page 8: ...sultant damage produced in the equipment described in this manual and associated installation if the instructions given have not been followed TECNOLAMA reserves the right to modify the product or spe...

Reviews: