AUTOMATIC DOORS FOR LIFTS
CONTROL INPUTS
12
Opening Signal.
Is a signal that orders the door to open. The tension to apply could be from 12 V DC to 60
V DC or 120 V AC to 230 V AC, with an external supply between this input and common
(10).
13
Serial Port.
The serial port is used to connect with external devices like the diagnostic console,
interfaces and future expansion devices. Operating speed 1.200 Baud per second, current
loop. It is used a RJ11 connector (phone jack connector).
17 / 18 / 19 / 20 Photocell.
One of the most relevant characteristics of this control
is the optional incorporation of the Fermator photocell.
It is composed by a emitter and receptor infrared.
21
Re-open.
This signal is used for installing the cabin door switch or an external barrier.
In order to active this signal, connect the re-open input (21) with the +12 V (23). Use
voltage free contacts. The reopening signal has priority over the closing signal.
23
+ 12 V Com.
This terminal is used for giving with an isolated contact a reopening order or a slow closing.
Always use voltage free contacts and usually open.
SERIAL PORT CONNECTION
CONNECTION OF THE PHOTOELECTRIC DETECTOR
20
19
18
17
PHOTOCELL
(
+
) White
(
+
) White
(
-
) Black
(
-
) Black
Green
Yellow
Receiver
Emitter
CONNECTION OF THE «OTHER INPUTS»
26
21
25
23
FLOOR LEVEL
RE-OPEN
SLOW CLOSE
+
12 V COM
OTHER INPUTS