background image

5

VF5

AUTOMATIC DOORS FOR LIFTS

 CONTROL INPUTS

12 

Opening Signal.

 

Is a signal that orders the door to open. The tension to apply could be from 12 V DC to 60 

V DC or 120 V AC to 230 V AC, with an external supply between this input and common 

(10).

13 

Serial Port.

 

The  serial  port  is  used  to  connect  with  external  devices  like  the  diagnostic  console, 

interfaces and future expansion devices. Operating speed 1.200 Baud per second, current 

loop. It is used a RJ11 connector (phone jack connector).

17 / 18 / 19 / 20  Photocell.

 

One of the most relevant characteristics of this control 

is the optional incorporation of the Fermator photocell. 

It is composed by a emitter and receptor infrared.

21 

Re-open.

 

This signal is used for installing the cabin door switch or an external barrier. 

 

In order  to active this signal, connect the re-open input (21) with the +12 V (23). Use 

voltage free contacts. The reopening signal has priority over the closing signal.

23 

+ 12 V Com.

 

 

This terminal is used for giving with an isolated contact a reopening order or a slow closing.

Always use voltage free contacts and usually open.

SERIAL PORT CONNECTION

CONNECTION OF THE PHOTOELECTRIC DETECTOR

20
19
18
17

PHOTOCELL

(

+

) White

(

+

) White

(

-

)  Black

(

-

)  Black

Green

Yellow

Receiver

Emitter

CONNECTION OF THE «OTHER INPUTS»

26
21
25
23

FLOOR LEVEL

RE-OPEN

SLOW CLOSE

+

 12 V COM

OTHER INPUTS

Summary of Contents for VCI-VF5A.CD0 Series

Page 1: ...ENG Assembly manual Automatic horizontal sliding car door Component VF5 Electronic Module AUTOMATIC DOORS FOR LIFTS MAN MMCAENGV5TC 10 2017...

Page 2: ...lose 100 230V AC DC PM ASYNC 13 Derecha Right QCI VF5A CD0EE ENCODER 12 V COM CERRAR LENTO SLOW CLOSE REABRIR RE OPEN SE AL DE PISO FLOOR LEVEL ENTRADAS PRIORITARIAS PRIORITY INPUTS FOTOC LULA PHOTOCE...

Page 3: ...s to open In the absence of a signal the doors will remain static If both inputs are applied then the open signal has priority 2 Automatic Semiautomatic ON Automatic Operators with skate automatic lan...

Page 4: ...from the supply It is important that the Door Operator Module has a GOOD EARTH CONNECTION The circuit can work with external voltage inputs or internal voltage input voltage free contact 8 Close signa...

Page 5: ...trol is the optional incorporation of the Fermator photocell It is composed by a emitter and receptor infrared 21 Re open This signal is used for installing the cabin door switch or an external barrie...

Page 6: ...0 41 Obstruction Led indicator and relay activated when an obstacle is detected that stops the doors from closing The signal will reset when the doors reach the opened or closed position Note In USA m...

Page 7: ...rocessor will calculate the acceleration and deceleration ramps and the braking torque required to give the optimum control of the doors 52 Close speed The door closing speed can be independently adju...

Page 8: ...te of the photocell Priorities 1 21 23 Reopening 2 Obstacle 3 25 23 Slow Closing 4 17 20 Photocell 5 8 Close SLAVE 2 INPUTS Configuration 1 ON 2 Inputs 2 Depends on type of door 3 Depends on type of d...

Page 9: ...with this configuration then there is a mechanical problem or electric motor or controller not supplied 6 Place the door in a middle position in order to see the starting movement 7 Switch on the VF...

Page 10: ...the encoder if nothing solves it The door opens instead of close Verify the DIP switch 3 position Reverse 2 phases of the motor connection 56 The door makes the learning phase correctly but the skate...

Page 11: ...e correct cable emitter to the yellow cable and receiver to the green one B Connect the photocell on the operator Even if you will not install the photocell make the learning of the photocell to avoid...

Page 12: ...is the clear entrance of any controller that has never been adjusted Therefore an autoadjustment is required check the autoadjustment process The door opens but doesn t close Check if the photocell L...

Page 13: ...of the motor and consequently the encoder is sending a wrong information Adjust the belt tension and make the autoadjustment again The system gets power but doesn t work and the led ON is off Check i...

Page 14: ...oltage supply 230 V Power 250 W Nominal torque 1 5 N m Nominal speed 900 RPM Thermic class F 155 C MOTOR PM Synchronous permanent magnet 10 pole Voltage supply 88 V Power 63 W Nominal torque 1 N m Nom...

Page 15: ...ioned below conform with the following E U council directives European Directive 2014 30 EU on Eelectromagnetic Compatibility EMC in accordance with the Product family standard for lifts escalators an...

Page 16: ...ge produced in the equipment described in this manual and associated installation if the instructions given have not been followed TECNOLAMA reserves the rights to modify the products specifications o...

Reviews: