Pag 14
Memokey
Memokey
1. Disconnect the system’s power supply.
2. Short-circuit the “S2” and ground.
If the system is equipped with a PI exit button, just press
and hold it down (refer to the installation diagram).
3. Reconnect the system’s power supply and remove the
short-circuit (or release the exit button) within 5 seconds.
4. If the process has been carried out correctly a double “beep”
will sound and the green light will stay on. Next enter the
following code
A708B9
. A double “beep” will sound and
the system will reset itself, restoring its factory settings.
NOTE:
The restoration of default factory settings does
not delete the rest of the information programmed on the
system.
Add or Edit User Codes (00 .....99)
The codes are stored in the memory in sequence:
position
- code - action
. Allows up to 100 access codes be stored.