TECHNICAL FEATURES

Power Supply:

 12 Vdc/Vac.

Operating Temperature:

 -20º to 55º C.

Capacity:

 100 Access Codes Non-Volatile Memory. 

Consumption:
  * On standby: 

 

 

 

 

40 mA

  *  With the lock-release relay active: 

110 mA 

Panel Connectors:

+, -

: 12 Vdc Power Supply.

C1, R1:

 relay output 1 (potential free) 

- C1:

 

relay 1 common wire (lock-release).  

- R1:

 

 Normally open (NA) or normally closed (NC) 

contact (based on confi guration).  

C2, R2:

 relay output 2 (potential free) 

- C2:

 

relay 2 common wire (lock-release).  

- R2:

 

 Normally open (NA) or normally closed (NC) 

contact (based on confi guration).  

A:

 auxiliary/panic output.  Collector Output Open.  Maximum 

current of 125 mA 

Summary of Contents for 100 CODE MEMOKEY cityline

Page 1: ...USER INSTALLER S MANUAL ENGLISH 100 CODE MEMOKEY 9 8 7 6 5 4 3 2 1 A B 0 cityline 9 8 7 6 5 4 3 2 1 A B 0 skyline ...

Page 2: ...ed in subsequent editions of this document ENGLISH This kit is programmed at the factory with 3 default codes The preprogrammed codes are different for each unit there fore you are the only one to know them You can use this codes to test the equipment operation as well To test the code dial the the one corresponding to the de vice you want to verify These codes are shown in a sticker in the back s...

Page 3: ...14 Deleting User Codes 16 Allowing User Codes to be Changed 17 Changing the Free Access Code 18 Activating Deactivating the Free Access Button 20 Enabling Disabling the Exit Buttons interior 21 Timing Lock Release Activat Relays and Aux Devices 22 Enabling the Auxiliary Output AUX 24 Quick Programming Guide 26 Technical Features 29 Wiring Diagram 30 PROGRAMMING MANUAL INDEX Introduction 31 Keypad ...

Page 4: ...s enabled any user can modify their personal access code without knowing the Master code The system has an auxiliary output which supplies a maximum of 125mAto connect activate another device auxiliary relay alarm or a speaker with the memokey itself generating an alarm tone It is equipped with 2 auxiliary inputs for the exit button Free Access Codes Key Press Confirmation via an acoustic tone Sys...

Page 5: ...s and Signal Leds The Memokey has a series of acoustic tones and leds which advise as to the system s current status beep x3 correct moc incorrect beep 1 second Lock Release Acoustic Tones Each time an access code programming code or configuration setting is entered the system emits a different tone depending on whether the data entered is correct or not ...

Page 6: ...d by default with a 4 digit code As such the user codes and MASTER code are 4 digits in length If you require greater security you can change the length to 5 or 6 digits See the chapter on Establishing the User Code Length 9 8 7 6 5 4 3 2 1 A B 0 RED GREEN DEFINITION No Power Normal mode awaiting access code entry programming Device Powered Up Opening Door Quick Flashes Programming Mode Slow Flash...

Page 7: ... each of the functions in programming mode enter the corresponding function code for example A4 code length At this point the system once again emits 3 beeps to advise that the setting entered is correct and the green led flashes in a slow sequence 9 8 7 6 5 4 3 2 1 A B 0 3 Then a new value is entered to be assigned to the function selected for example selecting a code of 6 digits in length Press ...

Page 8: ...ength 148036 If for any reason we need to reset the master code having forgotten the previous one refer to the corresponding chapter Restoring Factory Settings this will be the master code established for this operation Below are all the system functions and the configuration steps for each of these ...

Page 9: ...t is the following NOTE If you forget the Master code you can reset it to the default code of 1480 as explained in the Restoring the Master Code section A master code cannot be a user code and vice versa 1 Enter programming mode Code Master 1480 Bip 3 x 2 Enter the relevant option A0 Bip 3 x 3 Indicate the new Master code New Master Code Bip 3 x Example New Master Access Code for Program ming 1234...

Page 10: ... Master 1480 Bip 3 x 2 Enter the relevant option A4 Bip 3 x 3 Indicate the new length 4 5 or 6 Bip 3 x Example 6 Digit Access and Master Codes 1480 A4 6 NOTE If once the user codes have been programmed their length is changed to include a greater number of digits additional zeros will be added to the existent codes to bring them in line with the new length e g User Code 4 digits 1234 select a grea...

Page 11: ...e 4 4 digits 1234 If additional digits are to be re added to the existing codes the original digits will automatically be re added e g User Code 4 digits 1234 select a greater nº of digits For example 6 6 digits 123456 Each time the code length is changed the existing codes should be reset to avoid the codes being deleted or overwritten The configuration of code length should be done before settin...

Page 12: ... length 159357 If for any reason we need to reset any of these codes having forgotten the previous one refer to the corresponding chapter Restoring Factory Settings these are the codes that will be set on undertaking the operation in line with the code length established on the system Full Code Reset A9 This operation allows deletion of all existing access codes in the system s memory ...

Page 13: ...t is impossible for anyone without physical access to the equipment to modify it in any way NOTE Resetting is an irreversible operation whereby any previously stored codes cannot be recovered 1 Enter programming mode Code Master 1480 Bip 3 x 2 Enter the relevant option A9 Bip 3 x 3 Re enter the master code set by default as 1480 to confirm all codes have been deleted 1480 Bip 3 x Example Reset all...

Page 14: ...ithin 5 seconds 4 If the process has been carried out correctly a double beep will sound and the green light will stay on Next enter the following code A708B9 A double beep will sound and the system will reset itself restoring its factory settings NOTE The restoration of default factory settings does not delete the rest of the information programmed on the system Add or Edit User Codes 00 99 The c...

Page 15: ... code length must coincide with that esta blished on the system New Access Code Bip 3 x 4 Enter the associated action 1 The door will open Relay 1 2 The auxiliary devi ce will be activated if exists Relay 2 3 The door will open and the auxiliary de vice will be activated simultaneously 1 2 or 3 Bip 3 x Example New access code 1111 saved in the 00 position 1480 00 1111 1 ...

Page 16: ... that a list is prepared of the codes their positions and actions Deleting User Codes AA It is possible to delete a specific user code The procedure to follow is the following 1 Enter programming mode Code Master 1480 Bip 3 x 2 Enter the relevant option AA Bip 3 x 3 Enter the position of the access code to be deleted in the system s memory 00 99 Bip 3 x Example Delete the access code saved in the ...

Page 17: ...rreversible such that once a code has been deleted it cannot be recovered Allows user codes to be changed by users themselves A7 Users can change their assigned access code for another code of their choice if they wish To do this the following option must be enabled NOTE See the User Manual Section 1 Enter programming mode Code Master 1480 Bip 3 x 2 Enter the relevant option A7 Bip 3 x Example All...

Page 18: ... activates the lock release This function is especially useful when you want to offer free access to an area to be controlled Entering the free access code by default 1593 the button remains enabled until this code is re entered at which point it will be disabled 1 Enter programming mode Code Master 1480 Bip 3 x 2 Enter the relevant option A1 Bip 3 x 3 Enter the Free Access Code New Free Ac cess C...

Page 19: ...igit length 15935 6 digit length 159357 4 Enter the associated action 1 The door will open Relay 1 2 The auxiliary device will be activated if exists Relay 2 3 The door will open and the auxiliary de vice will be activated simultaneously 1 2 or 3 Bip 3 x Example Create a Free Access Code 5251 to open the door 1480 A1 5251 1 ...

Page 20: ...until this code is re entered at which point it will be disabled 1 Enter the free ac cess code 1593 by default Free Access Code 1593 Bip 3 x 2 Button Enabled Example Enable the free access button 1593 4 Re enter the free access code 1593 by default Free Access Code 1593 Bip 3 x 5 Button Disabled Example Disable the free access button 1593 ...

Page 21: ...ed in the interior of the building and allow you to open the door relay activation from inside or activate an additional electronic device installed These buttons can be enabled or disabled in the following way 1 Enter programming mode Code Master 1480 Bip 3 x 2 Enter the relevant option A5 1 Button Relay 1 A6 2 Button Relay 2 A5 or A6 Bip 3 x ...

Page 22: ...s or it can also operate in bistable mode the first valid code activates the relay and the next one deactivates it 3 Enter the associated action 0 Button Disabled 1 Button Enabled Action the door will open Relay 1 2 Button Enabled Action the auxiliary device will be activated if exists Relay 2 3 Button Enabled Action the door will open and the auxiliary device will be ac tivated simultaneously 0 1...

Page 23: ... Code Master 1480 Bip 3 x 2 Enter the relevant option A2 Relay 1 lock release A3 Relay 2 additional electrical device activa tion A2 or A3 Bip 3 x 3 Enter the new activation code or select bistable mode 00 Bistable Mode 01 99 01 to 99 se conds Bip 3 x 4 Enter 1 if the device is normally deactivated Enter 0 if the device is normally activated 1 or 0 Bip 3 x Example Change the re lay timing to 5 sec...

Page 24: ...iliary output which can be connected to a 12 Vdc device with a maximum current of 125 mA to carry out various functions Where the equipment to be connected does not adjust to these specifications a relay should be used Ref 2013 1 Enter program ming mode Code Master 1480 Bip 3 x 2 Enter the relevant option A8 Bip 3 x ...

Page 25: ...iated device 3 The all purpose output will switch every time a valid code is entered 4 The all purpose output will be activated and will remain active every time you press A and a valid keypad code purpose output will remain during 1 minute active 5 The all purpose output activates once 5 erroneous codes are entered in order and will remain active for 5 minutes or until a valid code is entered 6 T...

Page 26: ...y Activation Time Relay 1 A3 Programming the Auxiliary Device Time Relay 2 A4 Changing the code length from 4 to 6 figures A5 Enabling Disabling the P1 lock release exit button Relay 1 A6 Enabling Disabling the P2 auxiliary device button Relay 2 A7 Enabling Disabling the option for users to change their code A8 All Purpose Device Auxiliary Output Configuration which is called AUX A9 Delete all Cod...

Page 27: ...y Position Access Code 4 to 6 digits associated action 1 2 or 3 1480 02 1144 1 AA 00 99 Memory Posi tion of the Code to be Deleted 1480 AA 02 A0 New Master Code 1480 A0 1234 A1 New Free Access Code A2 A3 00 Bistable Mode 01 99 01 to 99 se conds 1480 A2 00 0 1480 A2 05 1 A4 4 5 or 6 1480 A4 6 ...

Page 28: ...ed Lock Release Relay 1 1480 A5 1 2 Button Enabled Activate auxi liary devices Relay 2 1480 A5 2 3 Button Enabled Activate door auxiliary device simultaneously 1480 A5 3 A7 Allowing User Codes to be Chan ged 1480 A7 A8 All Purpose Device Auxiliary Out put Configuration 0 1 2 3 4 5 or 6 1480 A8 1 A9 Code Master 1480 1480 A9 1480 ...

Page 29: ...ve 110 mA Panel Connectors 12 Vdc Power Supply C1 R1 relay output 1 potential free C1 relay 1 common wire lock release R1 Normally open NA or normally closed NC contact based on configuration C2 R2 relay output 2 potential free C2 relay 2 common wire lock release R2 Normally open NA or normally closed NC contact based on configuration A auxiliary panic output Collector Output Open Maximum current ...

Page 30: ...UXI LIARY OUTPUT Memokey Connections PI1 Output Button S1 Button to open the door from inside PI2 Exit Button S2 Auxiliary Electronic Device Activation Button PAL Free Access Button TRADE Optional button to allow free access to the building Notes The operating parameters for the free access auxiliary exit all purpose and lock release buttons are configurable Use a lock release suitable for the pow...

Page 31: ...se of offices In the case of personalised codes we can prohibit the use of any code by a specific user just by deleting the code from the system Management of all these personalised codes activation deac tivation etc is done by the system administrator USER MANUAL NOTES The SYSTEM ADMINISTRATION can assign a personal code for opening the door and or activate auxiliary devices for any of the author...

Page 32: ...s the door and generates an alarm tone where this option has been configured Free Access Entering this code the door will remain open until the free access code is re entered Changing the Code Users can change their own personal code if this option has been enabled by the SYSTEM ADMINISTRATOR Keypad Operation ...

Page 33: ...this section to each of the users User __________________________________________________ Code _____________ Emergencies Free Access Change Code A CODE AB CODE to be changed NEW _____________ This option should be enabled Contact the system administrator ...

Page 34: ...Pag 34 Memokey Memokey ...

Page 35: ...Pag 35 Memokey Memokey ...

Page 36: ......

Reviews: