The distance between the two faces has to be as great as possible (

between 3 and 4 mm

) so that the pressure applied by the door handle

on the brass window is controlled. This also increases the lifetime of the product and allows for smoother closing.

Given that the operation is very tight for correct opening but without excessive power consumption, you must ensure that the lock receives

stable 12 v

 supply and the specified 

amperage

. We thus recommend the use of power supplies and transformers that have sufficient

power for the lock without exceeding 12V.

The electrically-operated lock can be powered either using direct or alternating current. However, 

better operation

 has been noted 

using

alternating current

 as the variation in current means that even if there is a slight power failure the lock opens in a short period of time.

For direct current operation we have installed a diode to protect the installation from possible  overvoltage. If you plan to use this type of

current and this is not specified in the order, then we recommend that you install a diode.

To ensure that the device receives a voltage of 12V the 850 model can be used with an additional 

booster

. This produces an increase

in the initial power supplied, thus guaranteeing its operation even in older buildings where significant power failures may occur. The booster

has to be installed in parallel and as close as possible to the electrical section to ensure the optimal functioning of the system.

             

  ELECTRICAL CHARACTERISTICS

1 V

-10ºC / 50ºC

Vdc --  1350 mA

Vac --    990 mA

12 Vac / Vdc

8 Ohmios

Ohmios

INSTALLATION GUIDE:

It is better to install the 

ramp shaped accessory 

in the

entry to the electrical section to facilitate the entry of the

door handle, thus reducing the force required to close

the door, vibration and noise, whilst also substantially

increasing the door handle’s lifetime (as the door handle

receives less impact upon closing).

The lock has to be installed in the 

centre of the electrical

section

 so that the lever head can be freely retracted.

If the door tends to open then the friction reducing nipples

on the side of the level housing will have to be filed down

(in the gap of the electrical section you can see two

nipples on each side; the nipples closest to the opening

direction should be filed - in an outwards direction, never

downwards). In addition a door closer should be installed

to centre both sections automatically.

Friction-reducing

nipples

Centred on

its housing

Filing direction

Opening direction

Nipples to be filed,

depending on the

opening direction

        Lever head

Rear of the electrical