Regular cleaning helps reduce the risk of transmitting disease and enables the 

equipment to function at its optimum

. 

 
 

5.b Maintenance  
 
The Saver Safe Chair requires regular informal visual checks. Set up and follow your 
own maintenance schedule but use the following as a minimum. 
 
More  frequent  maintenance  will  be  required  in  situations  of  heavy  use.  If  any 
damage is discovered, take the Chair out of service until repair or replacement can 
be made. 

 

Action 

As Needed 

Each Month 

Disinfecting  

h

h

h

h

 

 

Cleaning  

h

h

h

h

 

 

Inspection  

h

h

h

h

 

h

h

h

h

 

Lubrication 

h

h

h

h

 

 

 

When using any product for maintenance, follow the manufacturers’ guidelines and 
read the manufacturers’ material safety data sheet. 
 

 

WARNING 

Improper maintenance can cause injury. Maintain the Chair only for the 

purpose described in this manual. 

 

5.c Disinfection 
 
Disinfect all surfaces of the Chair including the patient restraints. Follow disinfectant 
manufacturers’  directions  for  use.  Spray  or  wipe  disinfectant  onto  the  patient 
restraints. Do not immerse in disinfectant.  

 
 

5.d Cleaning 
 
Clean the Chair and its components with a clean cloth or soft brush and warm soapy 
water.  Rinse  with  warm  water  and  air  dry.  Do  not  clean  with  products  containing 
bleach or phenol. A stiff bristled brush can be used if necessary.   

 

WARNING 

Never leave a patient unattended in the Chair and always use restraints. 

 
 
 
 

Summary of Contents for Saver Safe Chair

Page 1: ...User Manual Saver Safe Chair FEBRUARY 2012...

Page 2: ...ient handling device designed to transport a patient person in a seated position up or down stairs and also on level ground The Ferno Saver Safe Chair is intended for use by fully trained and competen...

Page 3: ...Consider the mobility of existing employees and visitors as well as potential limitations of anyone accessing the site in future This must take into account their physical mental including learning an...

Page 4: ...an illness before or during the evacuation Anyone with a temporary problem including visitors and staff confusion anxiety or distress as a result of the situation Pregnant Women A parent with one or m...

Page 5: ...stand the instructions in this manual Trainees should be tested to verify their understanding of the Chair operation Training records for all trained operators should be kept Annual refresher training...

Page 6: ...floor and adjust the handle to the required height by holding the chair in place with your foot and pulling upwards on the handle The Handle can be lowered using the release button located on the insi...

Page 7: ...ady for 3c Transporting the chair down stairs Ferno recommends that two or more operators are used when evacuating patients who weigh more than 80Kg See section 4 for instructions if using 2 operators...

Page 8: ...a landing is reached turn the chair by slightly lifting the weight onto the front wheels and pushing the Chair round the bend until the chair is level and square with the top of the next flight of st...

Page 9: ...intenance 5a Checking the Saver Safe Chair The following informal visual checks are required to be carried out by the end user on a monthly basis or before use of the chair Overall cleanliness of the...

Page 10: ...tion h h h h When using any product for maintenance follow the manufacturers guidelines and read the manufacturers material safety data sheet WARNING Improper maintenance can cause injury Maintain the...

Page 11: ...Max Min 133 4cm extended 92 71cm retracted Overall width 52 7cm Overall Depth 91 4cm Weight 10 5 Kg Max Load Capacity 180 Kg FOLDED Height 103cm Width 52 7cm Depth 25 4cm All dimensions are approximat...

Page 12: ...s of the customer For service maintenance and any questions regarding this or any other Ferno product please contact Ferno House Stubs Beck Lane Cleckheaton West Yorkshire England BD19 4TZ Telephone 4...

Page 13: ...d BD19 4TZ Tel 44 0 1274 851999 Fax 44 0 1274 851111 e mail service uk ferno com As our policy is one of continuous development Ferno UK Ltd reserves the right to change the specifications without not...

Reviews: