background image

SKY F

14

EN

cod. 3540Z105  -  Rev. 01 - 01/2018

5. TECHNICAL DATA AND CHARACTERISTICS

Table. 7- Legend - figures cap. 5

5.1 General view and main components

fig. 13 - General view

5.2 Plumbing diagrams

fig. 14 - Water circuit

5.3 Technical data table

5

Sealed chamber

28

Fume manifold

7

Gas inlet - Ø 1/2”

29

Fume outlet manifold

8

DHW outlet - Ø 1/2”

38

Flow switch

9

DHW inlet - Ø 1/2”

44

Gas valve

16

Fan

73

Antifreeze thermostat (not supplied)

19

Combustion chamber

81

Ignition and detection electrode

20

Burner assembly

187

Fume baffle

21

Main nozzle

288

Antifreeze kit (optional) code 013009X0

22

Burner

R1 - R2 - R3 - R4

 Electric heaters

27

Copper exchanger

344

Double sensor (DHW + Safety)

44

81

19

27

16

5

28

344

20

21

22

29

38

187

9

7

8

Data

Unit

SKY F 11

SKY F 14

SKY F 17

PRODUCT IDENTIFICATION CODES - G20

0AF94IAA

0AF95IAA

0AF97IAA

PRODUCT IDENTIFICATION CODES - G31

0AF94KAA

0AF95KAA

0AF97KAA

COUNTRIES OF DESTINATION

IT

GAS CATEGORY - G20

II2H3B/P

GAS CATEGORY - G31

II2H3+

Max. heating capacity

kW

21.7

26.9

32.9

(Q)

Min. heating capacity

kW

8.3

10.3

12.6

(Q)

Max. heat output

kW

19.2

23.9

29.2

Min. heat output

kW

7.1

8.8

10.7

Pmax efficiency

%

88.5

88.7

88.9

Burner nozzles G20

no. x Ø

10 x 1.25

12 x 1.25

14 x 1.25

Gas supply pressure G20

mbar

20.0

20.0

20.0

Max. gas pressure at burner

mbar

13.0

14.0

15.0

Min. gas pressure at burner

mbar

2.0

2.0

2.0

Max. gas flow G20

m

3

/h

2.30

2.85

3.48

Min. gas flow G20

m

3

/h

0.88

1.10

1.33

Burner nozzles G31

no. x Ø

10 x 0.77

12 x 0.77

14 x 0.77

Gas supply pressure G31

mbar

37

37

37

Max. gas pressure at burner

mbar

35.0

35.0

35.0

Min. gas pressure at burner

mbar

5.0

5.0

5.0

Max. gas flow G31

kg/h

1.70

2.11

2.58

Min. gas flow G31

kg/h

0.65

0.80

0.99

Max. working pressure

bar

10

10

10

(PMS)

Min. working pressure

bar

0.20

0.20

0.20

DHW flow rate 

t 25°C

l/min

11.0

13.7

16.8

DHW flow rate 

t 50°C

l/min

5.5

6.9

8.4

(D)

Protection rating

IP

X5D

X5D

X5D

Power supply voltage

V/Hz

230V

230V

230V

Electrical power input

W

40

40

55

Empty weight

kg

13

14

17

Type of unit

C

12

-C

22

-C

32

-C

42

-C

52

-C

62

-C

72

-C

82

-B

22

8

9

38

344

Summary of Contents for SKY 11 F

Page 1: ... 2018 SKY F 595 E A 11 F 14 F 17 F A mm 295 335 375 C D B E mm 210 250 290 Modello 195 200 118 C B D 40 50 50 27 IT ISTRUZIONI PER L USO L INSTALLAZIONE E LA MANUTENZIONE EN INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE ...

Page 2: ...a funzione anomalia combustione 10 Connessione Service Tool Indicazione durante il funzionamento Durante la richiesta sanitario generata dal prelievo d acqua calda sanitaria il display part 5 fig 1 visualizza l attuale temperatura d uscita dell acqua calda sanitaria Anomalia In caso di anomalia vedi cap 4 4 il display part 5 fig 1 visualizza il codice di guasto e durante i tempi di attesa di sicur...

Page 3: ...NE LEGGERE LE ISTRUZIONI DI INSTALLAZIONE E DI MANUTENZIONE PRI MA DI INSTALLARE L APPARECCHIO RISPETTARE ANCHE LE INTRUZIONI DI PROGETTAZIONE Avvertenze L apparecchio è di tipo C a camera stagna e tiraggio forzato l ingresso aria e l uscita fumi devono essere collegati ad uno dei sistemi di evacuazione aspirazione indicati di seguito L apparecchio è omologato per il funzionamento con tutte le con...

Page 4: ...attivare la modalità TEST Lo scaldabagno si accende al massimo della potenza sanitario imposta ta come al paragrafo successivo Sul display verrà visualizzata la potenza sanitario fig 9 Modalità TEST potenza sanitario 100 Premere i tasti part 1 e 2 fig 1 per aumentare o diminuire la potenza Minima 0 Massima 100 Per disattivare la modalità TEST premere contemporaneamente i tasti part 1 e 2 fig 1 per...

Page 5: ... causano blocchi temporanei contraddistinte con la lettera F che ven gono ripristinati automaticamente non appena il valore rientra nel campo di funziona mento normale dello scaldabagno Lista anomalie Tabella 6 fig 10 Valvola gas A Presa di pressione a monte B Presa di pressione a valle I Connessione elettrica Valvola gas R Uscita gas S Entrata gas fig 11 Connessione valvola gas TYPE SGV100 Pi max...

Page 6: ...ORIA GAS G20 II2H3B P CATEGORIA GAS G31 II2H3 Portata termica max kW 21 7 26 9 32 9 Q Portata termica min kW 8 3 10 3 12 6 Q Potenza Termica max kW 19 2 23 9 29 2 Potenza Termica min kW 7 1 8 8 10 7 Rendimento Pmax 88 5 88 7 88 9 Ugelli bruciatore G20 n x Ø 10 x 1 25 12 x 1 25 14 x 1 25 Pressione gas alimentazione G20 mbar 20 0 20 0 20 0 Pressione gas max al bruciatore mbar 13 0 14 0 15 0 Pression...

Page 7: ...Ž Ěŝ ĞŶĞƌŐŝĂ ĞůĞƚƚƌŝĐĂ ŽŶƐƵŵŽ ĂŶŶƵŽ Ěŝ ĞŶĞƌŐŝĂ ĞůĞƚƚƌŝĐĂ ĨĨŝĐŝĞŶnjĂ ĞŶĞƌŐĞƚŝĐĂ Ěŝ ƌŝƐĐĂůĚĂŵĞŶƚŽ ĚĞůů ĂĐƋƵĂ ŽŶƐƵŵŽ ŐŝŽƌŶĂůŝĞƌŽ Ěŝ ĐŽŵďƵƐƚŝďŝůĞ ŽŶƐƵŵŽ ĂŶŶƵŽ Ěŝ ĐŽŵďƵƐƚŝďŝůĞ ŵƉŽƐƚĂnjŝŽŶŝ Ěŝ ƚĞŵƉĞƌĂƚƵƌĂ ƚĞƌŵŽƐƚĂƚŽ ƋƵĂůĞ ĐŽŵŵĞƌĐŝĂůŝnjnjĂƚŽ ŝǀĞůůŽ ĚĞůůĂ ƉŽƚĞŶnjĂ ƐŽŶŽƌĂ Ăůů ŝŶƚĞƌŶŽ ŵŝƐƐŝŽŶŝ Ěŝ ŽƐƐŝĚŝ Ě ĂnjŽƚŽ DĂƌĐŚŝŽ ZZK dŝƉŽ Ěŝ ƉƌŽĚŽƚƚŽ ĐĂůĚĂĐƋƵĂ ĐŽŶǀĞŶnjŝŽŶĂůĞ ŝŵďŽůŽ hŶŝƚă sĂůŽƌĞ YĞůĞĐ EtŚ YĨƵĞů t EKdž ŬtŚ ŬtŚ...

Page 8: ...SKY F 8 IT cod 3540Z105 Rev 01 01 2018 5 4 Schema elettrico fig 15 Circuito elettrico 81 1kW L N 230V 50 Hz 16 N L ABM02 73 R1 R2 R3 R4 288 T T 344 4 3 2 1 44 38 ...

Page 9: ...ƐƐĂ ƐĐůƵƐŝŽŶŝ ŽŶŽ ĞƐĐůƵƐŝ ĚĂůůĂ ƉƌĞƐĞŶƚĞ ŐĂƌĂŶnjŝĂ ŝ ĚŝĨĞƫ Ěŝ ĐŽŶĨŽƌŵŝƚă ĐĂƵƐĂƟ ĚĂ ͻ ƚƌĂƐƉŽƌƚŽ ŶŽŶ ĞīĞƩƵĂƚŽ Ă ĐƵƌĂ ĚĞůů ĂnjŝĞŶĚĂ ƉƌŽĚƵƩƌŝĐĞ ͻ ĂŶŽƌŵĂůŝƚă Ž ĂŶŽŵĂůŝĞ Ěŝ ƋƵĂůƐŝĂƐŝ ŐĞŶĞƌĞ ŶĞůů ĂůŝŵĞŶƚĂnjŝŽŶĞ ĚĞŐůŝ ŝŵƉŝĂŶƟ ŝĚƌĂƵůŝĐŝ ĞůĞƩƌŝĐŝ Ěŝ ĞƌŽŐĂnjŝŽŶĞ ĚĞů ĐŽŵďƵƐƟďŝůĞ Ěŝ ĐĂŵŝŶŝ Ğ Ž ƐĐĂƌŝĐŚŝ ͻ ĐĂůĐĂƌĞ ŝŶĂĚĞŐƵĂƟ ƚƌĂƩĂŵĞŶƟ ĚĞůů ĂĐƋƵĂ Ğ Ž ƚƌĂƩĂŵĞŶƟ ĚŝƐŝŶĐƌŽƐƚĂŶƟ ĞƌƌŽŶĞĂŵĞŶƚĞ ĞīĞƩƵĂƟ ͻ ĐŽƌƌŽƐŝŽŶŝ ĐĂƵƐĂƚĞ ĚĂ...

Page 10: ...on During a DHW demand generated by drawing domestic hot water the display detail 5 fig 1 shows the actual DHW outlet temperature Fault In case of a fault see cap 4 4 the display detail 5 fig 1 shows the fault code and during safety standby times the messages d3 and d4 2 3 Lighting and shutdown ATTENTION WHEN THE UNIT IS WORKING THE CASING MAY BE VERY HOT AVOID CON TACT RISK OF BURNS Connection to...

Page 11: ...ION OR INTOXICATION READ THE INSTALLATION AND MAINTENANCE INSTRUCTIONS BE FORE INSTALLING THE UNIT ALSO FOLLOW THE DESIGN INSTRUCTIONS Important The unit is a C type with sealed chamber and forced draught the air inlet and fume out let must be connected to one of the following extraction suction systems The unit is ap proved for operation with all the Cny flue configurations given on the dataplate...

Page 12: ... at the maximum DHW power set as described in the following section The DHW power will be shown on the display fig 9 TEST mode DHW power 100 Press the buttons details 1 and 2 fig 1 to increase or decrease the power Min 0 Max 100 To deactivate the TEST mode press the buttons details 1 and 2 fig 1 together for 5 seconds The TEST mode is automatically disabled in any case after 15 minutes or on stopp...

Page 13: ...art it is necessary to eliminate the fault Other faults marked with the letter F cause temporary shutdowns that are automati cally reset as soon as the value returns within the water heater s normal working range List of faults Table 6 fig 10 Gas valve A Upstream pressure point B Downstream pressure point I Gas valve electrical connection R Gas outlet S Gas inlet fig 11 Gas valve connection TYPE S...

Page 14: ...EGORY G20 II2H3B P GAS CATEGORY G31 II2H3 Max heating capacity kW 21 7 26 9 32 9 Q Min heating capacity kW 8 3 10 3 12 6 Q Max heat output kW 19 2 23 9 29 2 Min heat output kW 7 1 8 8 10 7 Pmax efficiency 88 5 88 7 88 9 Burner nozzles G20 no x Ø 10 x 1 25 12 x 1 25 14 x 1 25 Gas supply pressure G20 mbar 20 0 20 0 20 0 Max gas pressure at burner mbar 13 0 14 0 15 0 Min gas pressure at burner mbar 2...

Page 15: ...н ƚŽ Ϳ ĂŝůLJ ĞůĞĐƚƌŝĐŝƚLJ ĐŽŶƐƵŵƉƚŝŽŶ ŶŶƵĂů ĞůĞĐƚƌŝĐŝƚLJ ĐŽŶƐƵŵƉƚŝŽŶ tĂƚĞƌ ŚĞĂƚŝŶŐ ĞŶĞƌŐLJ ĞĨĨŝĐŝĞŶĐLJ ĂŝůLJ ĨƵĞů ĐŽŶƐƵŵƉƚŝŽŶ ŶŶƵĂů ĨƵĞů ĐŽŶƐƵŵƉƚŝŽŶ dŚĞƌŵŽƐƚĂƚ ƚĞŵƉĞƌĂƚƵƌĞ ƐĞƚƚŝŶŐƐ ŽĨ ƚŚĞ ǁĂƚĞƌ ŚĞĂƚĞƌ ĂƐ ƉůĂĐĞĚ ŽŶ ƚŚĞ ŵĂƌŬĞƚ ŽƵŶĚ ƉŽǁĞƌ ůĞǀĞů ŵŝƐƐŝŽŶƐ ŽĨ ŶŝƚƌŽŐĞŶ ŽdžŝĚĞƐ dƌĂĚĞŵĂƌŬ ZZK dLJƉĞ ŽŶǀĞŶƚŝŽŶĂů ǁĂƚĞƌ ŚĞĂƚĞƌ LJŵďŽů hŶŝƚ sĂůƵĞ YĞůĞĐ EtŚ YĨƵĞů t EKdž ŬtŚ ŬtŚ й ŬtŚ Ě ŵŐ ŬtŚ DK z ϭϳ y Ϭ Ϭϯϯ ϴϭ Ϯϰ ϵϮϳ D y ...

Page 16: ...SKY F 16 EN cod 3540Z105 Rev 01 01 2018 5 4 Wiring diagram fig 15 Electrical circuit 81 1kW L N 230V 50 Hz 16 N L ABM02 73 R1 R2 R3 R4 288 T T 344 4 3 2 1 44 38 ...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ... DEEULFDWR LQ WDOLD 0DGH LQ WDO 552 6 S Via 5LWRQGD D 6DQ RQLIDFLR 9HURQD 7 ZZZ IHUUROL FRP ...

Reviews: