1.7. Inspection Rules
Examination
Aluminium
rolling-up
METALLIC FRAME:
Assembly fixing
To tighten screws.
Once per year
To verify the soldering cord.
Once per year
Motoreductor
To verify the state and the wear of the break, as well as the correct
Once per year
operating mode of the break lever.
To verify the fixings motor screws.
Once per year
Rolling axis
To tighten fixings and bearings.
Once per year
Door blade
To verify the absence of fissures and stripes on the whole blade.
Once per year
To control blade fixings on the rolling axis as well as reinforcement bars.
Once per year
To control the electrical safety edge operating mode.
Once per year
Safety Edge
To verify the WIFI system.
Once per year
To verify the blade fixing, and the state of guides, cables spout and friction
pieces. Substitute all deformed friction pieces.
Once per year
To verify the state of contacts connector, cables and the electrical safety edge.
Once per year
Lateral frames
To verify the fixing and the vertical guides state.
Once per year
To control the cable way as well as the chain charged to conduct the energy.
Once per year
To verify the assembly and the operating mode of the photocell.
Once per year
To clean the photoelectrical barrier and the beam.
Once per year
Electrical control box and Added optional boards
To verify the entirety of the wiring map.
Once per year
To control the main switch and the closure of the control box.
Once per year
To verify the fixing.
Once per year
ELECTRICAL FUNCTIONS:
Run of the door
To control the opening and closure positions of the closure guides.
Once per year
To verify the fixing and the operating mode of the end of run switches.
Once per year
Security mechanisms and drive
To clean the optical of the security photoelectrical barrier.
Once per year
To verify the fixing and the operating mode of the end of run switches.
Once per year
Electrical components
To visually control and look for any kind of mechanical damage.
Once per year
Mechanical Functions
To verify the operating mode and the state of the couple support during the
Once per year
operating.
To examine the behaviour of the blade roll up.
Once per year
10