4.4. Electrical Control Box
Matrix 6 control box
·
4.4.1. Characteristics
·
The MATRIX 6 Control box
with 3 KW at 400V / 3~
as maximum with Mechanical limit Switch.
·
Status indication through LEDs through a two digits
digital indicator:
·
Mains voltage
-
400V / 3~
-
230V / 3~
-
230V / 1~ (for single phase motors with frequency
inverter)
· Industrial door operating mode.
-
Opening and closure by present man.
-
Automatic opening and closure by present man (without safety edge protector).
-
Automatic opening and closure (automatic closure combining with safety edge protector)
· Automatic detection and handling of three different safety edges types.
-
8K2 Normally active contact.
· Automatic closure.
-
After a waiting time (adjustable) from 1 up to 90 seconds as maximum.
-
The time can be reduced interrupting the photocell light beam.
-
it can be interrupted with auxiliary switch.
·
Connection to supply external devices.
·
Terminal block with indication to connect all necessary devices.
·
Push button with 3 buttons on the cover OPENING / STOP / CLOSURE.
·
Additional connections for control devices.
·
4.4.2. First steps
-
The control box is composed by a box with a
removing front cover.
-
Open the front panel and insert cables through
inferior holes on the box.
17