4.4.5. Wireless-band
Wireless-band tramsitter:
Connect the output rubber band electrical cable to terminals 1
and 2 on the Transmitter and activate the switch Nº1 to start the test.
Wireless-band receiver:
Connect the receiver supply, ter0 and 12/24v to terminals
5 and 6. Connect terminals C and S from receiver to “Banda palpadora” terminals on the
control box.
TRANSMITTER
CONTROL BOX
RECEIVER
C and S from the receiver
To connect transmitter and receiver
1- Connect the receiver feed. (Be careful to respect the polarity when you use a DC power
supply) 2- Check transmitter and receiver options.
3- Match emitter and receiver following the programming
steps. 4- Install the transmitter on the door.
5- Wire the resistive safety edge to the transmitter and connect
it. 6- Install the receiver in the suitable place.
7- Wire the power supply, the test input and the receiver output to the control
box 8- Activate the power supply.
9- Make a test with the connected safety edge with door in different positions, mainly
close to the opening and closure position.
10- We recommend to follow step 1 to 4 before to install the device. Respect a minimum
distance of 1m between transmitter and receiver to have the optimal operating mode. 11-
Once assembled and matched transmitter and receiver , you have to maintain the
transmitter’s microswitch in position Nº1.
The transmitter and the receiver are supplied already
configured to operate in couple.
If the programming is not correct, you can reprogram them
proceeding as following:
A- All switches of transmitter and receiver must be to in down position (OFF), except the
Nº1 on transmitter.
B-
Press the program button on the receiver and you will hear a “Beep” as validation. C
-
Then, you will be in programming mo
de and the “program” LED will light to indicate it.
20