Before operating with the door, check that engine plates are at 230V III position.
Rest of door and security complements set up must be done accordingly with
wiring diagram from standard instructions manual.
·
1.1.2. Frequency converter set up
Opening speed set up
Press MENU button on the frequency converter, and by turning and pressing in the middle
of the wheel, go to following parameter:
1CV converters
: RDY→CONF→HSP→65 (adjustable from 50 to 75)
2 and 3CV converters:
RDY→SET→HSP→60 (adjustable from 50 to 60)
Closing speed set up
Press MENU button on the frequency converter, and by turning and pressing in the middle
of the wheel, go to following parameter:
1CV converters:
RDY→CONF→FULL→FUN→P55→SP2→30 (adjustable from 15 to
50)
2 and 3CV converters
: RDY→ FUN→P55→SP2→30 (adjustable from 15 to 45)
Rest of frequency converter options must not be modified, as they are
adjustments for the proper door functioning.
5. Errors
To avoid to damage the door or to hurt to somebody, during the door’s repair, it is very
important to respect following points:
·
You have to rectify the error, through authorised staff.
·
Firstly, be sure that the door is protected against any involuntary reactivation, deactivating
the main switch.
·
Protect yourselves against any involuntary reactivation of the main switch, locking it or ask
to an other person to constantly check that the machine has been deactivated using a
security cut device with locking.
·
Protect the door action area.
·
You have a
lso to carefully read the chapter concerning “security information”.
·
5.1. Mechanics Errors
If the failure can not be corrected, please contact the After-Sale service of the supplier or
the manufacturer.
29