BLUEHELIX TECH RRT 28 C
171
EN
cod. 3541N260 - Rev. 01 - 10/2017
b10
Comfort burner on time (b01=1)
0-40 seconds
15 seconds
Not implemented (b01=2)
--
--
Not implemented (b01=3)
--
--
Not implemented (b01=4)
--
--
b11
Flowmeter timing (b01=1)
0=Deactivated, 1-10=seconds
0=Deactivated
Hot water tank preparation mode (b01=2)
0=Fixed primary, 1=Linked to setpoint, 2=Ramp
0=Fixed primary
Flowmeter timing (b01=3)
0=Deactivated, 1-10=seconds
0=Deactivated
Hot water tank preparation mode (b01=4)
0=Fixed primary, 1=Linked to setpoint, 2=Ramp
0=Fixed primary
b12
Modulation delta (b01=1)
0-30°C/10
0°C/10
Priority override - Activation (b01=2)
0-255 minutes
30 minutes
Modulation delta (b01=3)
0-30°C/10
0°C/10
Priority override - Activation (b01=4)
0-255 minutes
30 minutes
b13
Not implemented (b01=1)
--
--
Priority override - Deactivation (b01=2)
0-255 minutes
15 minutes
Not implemented (b01=3)
--
--
Priority override - Deactivation (b01=4)
0-255 minutes
15 minutes
b14
Pump antiblock operation time
0-20 seconds
5 seconds
b15
Flowmeter type selection (b01=1)
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow.
(190 imp/l)
2= Flowmeter (190 imp/
l)
No effect on adjustment (b01=2)
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow.
(190 imp/l)
2= Flowmeter (190 imp/
l)
Flowmeter type selection (b01=3)
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow.
(190 imp/l)
2= Flowmeter (190 imp/
l)
No effect on adjustment (b01=4)
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow.
(190 imp/l)
2= Flowmeter (190 imp/
l)
b16
Fan frequency in standby mode
0-100%
0%
b17
Winter icon selection
0=Deactivated, 1=Activated
0=Deactivated
b18
DHW mode activation flow rate (b01=1)
0-100l/min/10
25
No effect on adjustment (b01=2)
0-100l/min/10
25
DHW mode activation flow rate (b01=3)
0-100l/min/10
25
No effect on adjustment (b01=4)
0-100l/min/10
25
b19
DHW mode deactivation flow rate (b01=1)
0-100l/min/10
20
No effect on adjustment (b01=2)
0-100l/min/10
20
DHW mode deactivation flow rate (b01=3)
0-100l/min/10
20
No effect on adjustment (b01=4)
0-100l/min/10
20
b20
Flue material selection
0=Standard, 1=PVC, 2=CPVC
0=Standard
b21
PVC flue maximum temperature
60-110°C
88°C
b22
CPVC flue maximum temperature
60-110°C
93°C
b23
Standard flue shutdown maximum temperature 60-110°C
100°C
b24
PVC flue shutdown maximum temperature
60-110°C
93°C
b25
CPVC flue shutdown maximum temperature
60-110°C
98°C
b26
Not implemented
--
--
b27
Not implemented
--
--
b28
Installer menu code
100-199
123
b29
Restoring Factory Values
Change the value from 0 to 10 by pressing the
“DHW
+”
button. Confirm by pressing the
“h”
but-
ton.
-
P30
Heating ramp
1-20°C/minute
2°C/minute
P31
Virtual setpoint min. temperature (b01=1)
0=Deactivated, 1-80°C
0=Deactivated
Virtual setpoint min. temperature (b01=2)
0=Deactivated, 1-80°C
0=Deactivated
Virtual setpoint min. temperature (b01=3)
0=Deactivated, 1-80°C
0=Deactivated
Virtual setpoint min. temperature (b01=4)
0=Deactivated, 1-80°C
0=Deactivated
P32
Heating standby time
0-10 minutes
4 minutes
Contents Description
Range
Default