Disassembling the burner and cleaning the exchanger
fig. 40
•
Disconnect the power supply and close the gas tap upstream of the valve.
•
Undo the 5 screws securing the exchanger cover.
•
Undo the 3 screws securing the burner.
•
Check the correct distance of the electrodes.
•
Clean the inside of the exchanger with the accessories indicated in fig. 40.
3.5 mm
2