Connection with coaxial pipes
fig. 12- Examples of connection with coaxial pipes (
= Air /
= Fumes)
Table 2 - Typology
For coaxial connection, fit the unit with one of the following starting accessories. For the wall hole dimensions, refer to
the figure on the cover.
fig. 13 - Starting accessory for coaxial ducts
Table 3- Baffles for coaxial ducts
Table 4- Baffles for coaxial ducts
Type
Description
C1X
Wall horizontal exhaust and inlet
C3X
Roof vertical exhaust and inlet
Coaxial 60/100
Coaxial 80/125
Max. permissible length
DIVA D F24 = 5 m
DIVA D F32 = 5 m
10 m
Reduction factor 90° bend
1 m
0.5 m
Reduction factor 45° bend
0.5 m
0.25 m
Baffle to use
0 ÷ 2 m
DIVA D F24 = Ø43
DIVA D F32 = Ø45
0 ÷ 3 m
DIVA D F24 = Ø43
DIVA D F32 = Ø45
2 ÷ 5 m
no baffle
3 ÷ 10 m
no baffle
Coaxial 60/100
Coaxial 80/125
Max. permissible length
DIVA D F37 = 4 m
10 m
Reduction factor 90° bend
1 m
0.5 m
Reduction factor 45° bend
0.5 m
0.25 m
Baffle to use
0 ÷ 2 m
DIVA D F37 = Ø50
0 ÷ 3 m
DIVA D F37 = Ø50
2 ÷ 4 m
no baffle
3 ÷ 10 m
no baffle
C
1X
C
1X
C
3X
C
3X
C
3X
C
1X
Ø126
Ø82
Ø60
Ø130
Ø
100
010018X0
010006X0
100
60
45.6
010007X0
68
11
8
100
60