DIVA D F
59
EN
cod. 3542A640 - Rev. 00 - 11/2022
Notes:
1. Parameters with more than one description vary their function and/or range in relation to the setting of the parameter
given in brackets.
2. Parameters with more than one description are reset to the default value if the parameter given in brackets is mo-
dified.
To exit the configuration Menu press the DHW buttons together for 10 seconds, or exiting occurs automatically after 2
minutes.
Service menu
The card Service Menu is accessed by pressing the Reset button for 20 seconds. 4 submenus are available: press the
Heating buttons to select, in increasing or decreasing order, "tS", "In", "Hi" or "rE". "tS" means Transparent Parameters
Menu, "In" means Information Menu, "Hi" means History Menu: after selecting the submenu, press the Reset button
again to access it; "rE" means History Menu Reset: see description.
“tS” - Transparent Parameters Menu
21
parameters, indicated by the letter "P” are available, which are also modifiable from Remote Timer Control.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing order. Press the DHW buttons to
view or modify the value of a parameter: the change will be automatically saved.
Table 10
b09
DHW demand type selection
0 = Flow switch
2
1 = Flowmeter (190 imp/l)
2 = Flowmeter (450 imp/l)
3 = Flowmeter (700 imp/l)
b10
Flowmeter timing (b02=1)
0 = Deactivated
1 ÷ 10=seconds
0
Flowmeter timing (b02=2)
0=Deactivated
1-10=seconds
No effect on adjustment (b02=3)
--
No effect on adjustment (b02=4)
--
b11
DHW mode activation flow rate (b02=1)
10 ÷ 100 L/min/10
DHW mode activation flow rate (b02=2)
10 ÷ 100 L/min/10
15
No effect on adjustment (b02=3)
--
No effect on adjustment (b02=4)
--
b12
Enable Auto-Settings procedure
0 = Disabled
1 = Enabled
0
Index
Description
Range to use
DIVA D F
P01
Ignition ramp Offset
9 ÷ 19
15
P02
Heating ramp
1-20°C/minute
5
P03
Heating standby time
0-10 minutes
2
P04
Heating Post-Circulation
0-20 minutes
6
P05
Heating user max. setpoint
31-85°C
80
P06
Max. output in heating
0-100%
100
Index
Description
Range
Parameter