DIVA D F
60
EN
cod. 3542A640 - Rev. 00 - 11/2022
P07
Burner shutdown in DHW (b02=1)
0=Fixed
1=Linked to setpoint
2=Solar
3 = DO NOT USE
4 = DO NOT USE
Burner shutdown in DHW (b02=2)
0=Fixed
0
1=Linked to setpoint
2=Solar
3 = DO NOT USE
4 = DO NOT USE
Hot water tank hysteresis (b02=3)
0 (do not use) 1-2-3-4°C
Hot water tank hysteresis (b02=4)
0 (do not use) 1-2-3-4°C
P08
DHW standby time (b02=1)
0-60 seconds
30
DHW standby time (b02=2)
0-60 seconds
DHW standby time (b02=3)
0-60 seconds
DHW standby time (b02=4)
0-60 seconds
P09
DHW user max. setpoint (b02=1)
50-65°C
50
DHW user max. setpoint (b02=2)
50-65°C
DHW user max. setpoint (b02=3)
50-65°C
DHW user max. setpoint (b02=4)
50-65°C
P10
Anti-inertia function temperature (b02=1)
5-85°C
No effect on adjustment (b02=2)
--
0
Flow temperature in DHW (b02=3)
70-85°C
Flow temperature in DHW (b02=4)
70-85°C
P11
Anti-inertia function Post-Circulation (b02=1)
0-10 Seconds
DHW Post-Circulation (b02=2)
0-60 Seconds
30
DHW Post-Circulation (b02=3)
0-60 Seconds
DHW Post-Circulation (b02=4)
0-60 Seconds
P12
Max. output in DHW
0-100%
100
P13
Absolute min. output
0-100%
0
P14
Post-Ventilation
0=Default
0
1=50 seconds
P15
CO2 limit Offset (b03=0)
0 (Minimum)
30 (Maximum)
No effect on adjustment (b03=1)
--
No effect on adjustment (b03=2)
--
CO2 limit Offset (b03=3)
0 (Minimum)
30 (Maximum)
20
CO2 limit Offset (b03=4)
0 (Minimum)
30 (Maximum)
No effect on adjustment (b03=5)
--
P16
Exchanger protection intervention
0=No F43
10
1-15=1-15°C/second
P17
Modulating pump max. speed - absolute
Operating at 100%.
Adjustable with optional cable.
100
P18
Modulating pump max. speed - post circulation
0-100% not operating.
Always at 100% in this model
60
Index
Description
Range to use
DIVA D F