FERROLI F30
3
1. DESCRIPTION
1.01 Introduction
The
Ferroli F30
is defi ned as a “room sealed” combination boiler, all air required for combustion is taken from
outside the room in which it is installed. It is a new high performance gas fi red heat generator for central heating and
domestic hot water production. A special feature of this boiler is its built-in electronic fl ame ignition and control unit
making burner operation completely automatic and safe. The main components are as follows:
• Copper heat exchanger consisting of three fi nned tubes specifi cally shaped for high effi ciency.
• There are three copper coils inserted in the three heating circuit tubes. These represent the domestic hot water heat
exchanger. Their shape and high exchange surface area enable the full output of the boiler to be absorbed.
• Ceramic fi bre insulated combustion chamber
• 16 stainless steel bladed burners specifi cally designed for this boiler.
• Fan for discharge of combustion products and intake of combustion air.
• Differential air pressure switch. For safety reasons, this ensures the burner ignites only when the fan
is functioning correctly.
• Hermetically sealed compartment made from corrosion-resistant steel enclosing the above components.
• Combination gas safety valve with modulator, complete with pressure stabiliser.
• Flowmeter giving the domestic hot water circuit precedence over the central heating circuit.
• Pressure relief valve for the central heating circuit set to open at 3 bar.
• Built-in Expansion vessel.
• Variable speed pump.
• Central heating fl ow temperature adjustment thermostat.
• Domestic hot water fl ow temperature adjustment thermostat.
• Central heating limit thermostat.
• Overheat safety thermostat.
• Electronic control unit for automatic fl ame ignition and control.
• Central heating low water pressure cut off switch.
• Domestic hot water fl ow temperature sensor.
• Central heating fl ow temperature sensor.
• Safety bracket
1.02 Instructions and regulations
Assembly, installation, fi rst start up and maintenance must be carried out by competent persons only, in accordance
with all current technical regulations and directives.
C.O.S.H.H.
Materials used in the manufacture of this appliance are non hazardous and no special precautions are
required when servicing.
Related Documents
This appliance must be installed strictly in accordance with these instructions.
The Gas Safety Regulations (Installations & Use) 1996.
The Local Building Regulations.
The Building Regulations.
The Buildings Standards (Scotland - Consolidated) Regulations.
British Standards Codes of Practice:
B.S. 7593 1992
TREATMENT OF WATER IN DOMESTIC HOT WATER CENTRAL HEATING SYSTEMS
B.S. 5546 1990
INSTALLATION OF HOT WATER SUPPLIES FOR DOMESTIC PURPOSES
B.S. 5440 Part 1 2000 FLUES
B.S. 5440 Part 2 1989 AIR SUPPLY
B.S. 5449 1990
FORCED CIRCULATION HOT WATER SYSTEMS
B.S. 6798 1987
INSTALLATION OF GAS FIRED HOT WATER BOILERS
B.S. 6891 1989
GAS INSTALLATIONS
B.S. 7671 1992
IEE WIRING REGULATIONS
B.S. 4814 1990
SPECIFICATION FOR EXPANSION VESSELS
B.S. 5482 1994
INSTALLATION OF LPG
Model Water Bye Laws
For Northern Ireland the rules in force apply