3.04 Back fl ue outlet (Diagram 1-9)
Fig. 16a
Fig. 16b
Fig. 16c
1.
Core drill 127mm hole (5").
2.
Push through the outer fl ue.
3.
Gently pull back until wall seal
is fl ush with the wall.
Fig. 16d
4.
Place wall plate on outer fl ue
ensuring it is level. Mark and drill
four holes, two top, for expan-
ding bolts and two bottom for
plugs and screws. Fix plate to
wall with the square gasket
between the wall and the plate
use the large diameter washers
for the bolts and screws.
Square Gasket
Circular Gasket
Fig. 16e
5.
Through plate into air tube,
drill two holes and fi x in place
using two self tapping screws
M4 x 6mm long.
6.
Cut the outer fl ue fl ush with the
fl ange on the hanging plate.
Fig. 16f
7.
Insert the aluminium fl ue pipe
into white plastic outer flue,
making sure the aluminium pipe
sits fully and centrally into the
fl ue terminal. Mark the aluminium
fl ue pipe at the point it is fl ush
with the mounting plate. Add
36mm to this mark and cut the
aluminium inner flue pipe at
this point.
Fig. 16g
36 mm