10
DOMITOP HF 24 - 30 E
FERELLA GOLD HF 24 - 30 MEL
Version - 09.2002
1.4 Technical data table
Gas supply
Pmax
Pmin
Heating Power (Net Heat Value - Hi)
Heating Power (Gross Heat Value - Hi)
Useful heating power 80°C - 60°C
Powers
Pmax
Pmin
kcal/h 20,000
8,300
kW
23.3
9.7
kcal/h 24,700
10,700
kW
28.7
12.4
kcal/h 22,200
9,900
kW
25.8
11.2
Dimensions, weights connections
Depth
mm
272
Width
mm
460
Height
mm
760
Boiler water content
litres
1.5
Expansion tank pre-filling pressure
bar
1
Expansion tank capacity
litres
8
Minimum working pressure in heating
bar
0.8
Maximum working pressure in heating
bar
3
Maximum working temperature in heating
°C
90
Electrical protection rating
IP
44
Electrical power supply
Power voltage/frequency
V/Hz
220/50
Max electrical power absorbed
W
125
Heating system connection
3/4
Filling system connection
1/2
Gas system connection
inches
1/2
Weight with packing
kg
35
Heating
Natural Gas delivery (G20)
nm
3
/h
2.73
1.19
Natural Gas main nozzles (G20)
mm
12 x 1.30
Pressure at Natural Gas burner (G20)
mbar
11.8
2.5
Natural Gas supply pressure (G20)
mbar
20.0
LPG burner (G31)
Kg/h
2.00
0.87
LPG main nozzles (G31)
mm
12 x 0.77
Pressure at LPG burner (G31)
mbar
36.0
7.0
LPG supply pressure (G31)
mbar
37.0
Safety valve
bar
3
Pmax
Pmin
25,800 10,900
30.0
12.7
31,600 13,800
36.8
16.1
28,500 12,500
33.1
14.5
363
460
760
1.7
1
10
0.8
3
90
44
220/50
125
3/4
1/2
1/2
45
3.50
1.53
16 x 1.25
11.8
2.5
20.0
2.57
1.13
16 x 0.75
35.5
7.0
37.0
3
Pmax
Pmin
DOMITOP - FERELLA GOLD
24
KW
30
KW
inches
inches