11
DOMITOP HF 24 - 30 E
FERELLA GOLD HF 24 - 30 MEL
Version - 09.2002
2. PRODUCT FRAMEWORK AND INTERNAL
COMPONENTS
2.1 Hydraulic circuit heating
Hydraulic diagram for heating
When there is a call for heat, the room thermostat or control system make the burners ignite and the
circulation pump come into operation. The heat contained in the products of combustion is transferred to the
water by the system via the exchanger. For more details on the operating logic, refer to chap.3.
Key
5
Airtight chamber
7
Inlet
1 0
System delivery
1 1
System return
1 4
Safety valve
1 6
Fan
2 0
Burner assembly
2 9
Fume outlet manifold
3 2
Heating circulator
3 4
Heating temp. sensor
4 3
Air pressure switch
4 4
Gas valve
4 9
Safety thermostat
5 0
Heating thermostat
5 6
Expansion tank
7 4
Heating system cock
8 1
Ignition electrode
8 2
Detection electrode
8 4
1st gas valve operator
1 1 4
Water pressure switch
1 8 7
Fume diaphragm
2 2 2
Copper exchanger
43
49
50
56
81
44
32
20
82
222
5
29-187
16
74
14
114
34
- +
10
7
11