3. SERVICE AND MAINTENANCE
3.1 Settings
The adjustment of the software operations must only be performed by Qualified Personnel.
FERROLI S.p.A. declines all liability for damage to persons and/or things deriving from tampering with the
appliance by non-authorised persons.
Gas conversion
A conversion kit is required:
1
Remove jacket.
2
Open sealed room department.
3
Release
"A"
connection.
4
Change the injector using the one in the kit.
5
Re-tighten
"A"
and check that there are no gas
losses.
6
Once the regulation has been made, apply the
data plate contained in the conversion kit next to
the data plate and reassemble the boiler casing
and the lower protection plate.
7
Run the boiler.
Test mode
Press "
" and "
" keys together for 3 seconds
to enter mode.
Fig. 16
Fuel type
Ø
(G20)
6,70 mm
Catagorie
2E
(G31)
4,75 mm
3P