ECONCEPT TECH 35 A
9
EN
cod. 3540I341 - 04/2008 (Rev. 00)
Press the heating buttons
(details 3 and 4 - fig. 1) to access parallel curve offset; "OF" appears flashing
(fig. 11). Operate the DHW buttons
(details 1 and 2 - fig. 1) to adjust parallel curve offset according to the
characteristic (fig. 13).
fig. 11 - Parallel curve offset
Press the button
(detail 6 - fig. 1) again for 5 seconds to exit the “Sliding Temperature” menu.
If the room temperature is lower than the required value, it is advisable to set a higher order curve and vice versa. Pro-
ceed by increasing or decreasing in steps of one and check the result in the room.
fig. 12 - Compensation curves
fig. 13 - Example of parallel compensation curve shift
A
If the Remote Timer Control (optional) is connected to the boiler, the above adjustments are managed accord-
ing to that given in table 1.
eco
comfort
reset
20
30
40
50
60
70
80
90
85
20
10
0
-10
-20
1
2
3
4
5
6
8
9
10
7
20
30
40
50
60
70
80
90
85
20
10
0
-10
-20
1
2
3
4
5
6
8
9
10
7
20
10
0
-10
-20
20
30
40
50
60
70
80
90
85
1
2
3
4
5
6
8
9
10
7
OFFSET = 20
OFFSET = 40