40
ECOTRONIC Plus
© F
er
roli 08164 ECO
TR
ONIC Plus.monen.ind
d
System warning “
D
T too high“
Expert/
D
T too high
selection: “Yes“, “No“
factory setting: “Yes“
This message is shown, if solar loading has been carried out
for a period of 20 minutes with a differential higher than
50 K.
The message function can be deactivated by selecting
“No“.
System warnin
g
“Non-ret. valve“
Expert/non-ret. val.
selection: “Yes“, “No“
factory setting: “Yes“
This message is shown if between 11 p.m. and 5.00 a.m. the
collector temperature is higher than 40 °C or a store is
loaded because of a high temperature difference.
The message function can be deactivated by selecting
“No“.
Message relay (error message)
Expert/message rel.
selection: “Yes“, “No“
factory setting: “No“
Activate this function by selecting “Yes“. If the controller
detects a fault, the message relay is energised (e.g. for signal
lights).
These errors are:
• Sensor defective
• Real-time-clock (RTC) defective
• Storage module (EEPROM) defective
Please note that a message caused by one of the plausibility
controls (non-return valve,
D
T too high) does not activate
the relay.
Chimney sweeper
Expert/chimney
selection: “Yes“, “No“
factory setting: “No“
Expert/chimney sweeper
This function is used for activating a given relay state when
required.- e.g.flue gas measurement if the system controls
a boiler. Activate this function by selecting “Yes“.
Adjust the required relay status in the chimney sweeper
menu (expert / chimney sweeper).
If the chimney sweeper function is activated, “chimney
sweeper“ is indicated in the main menu.
Sensor offset
Expert/Sensors/CS-Type
selection: A, B, C, D, E
factory setting: E
Expert/Sensors/CS-Adjust
Expert/Sensors/CS-Offset
Expert/Sensors/Sensor 1 (...12)
adjustment range: -5,0 ... 5,0 K
factory setting: 0,0 K
Adjust the CS-type in this menu. The CS-type should be
matched to the code letter printed on the CS type label.
The CS-offset adjustment should be carried out with the
irradiation sensor disconnected.
Furthermore, an offset for sensors 1 ... 12 can be carried
out.
4.4 Menu: Expert